Document Detail


Effect on blood flow of rotation and position of the internal mammary artery pedicle.
MedLine Citation:
PMID:  7847959     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
The internal mammary artery is the preferred conduit for coronary artery bypass grafts. The effect on flow through the artery of both rotation and position of the artery pedicle was tested in an in-vitro setting on 20 arteries using a perfusate closely approximately the normothermic viscosity of blood. It was found that the effect of rotation on blood flow was highly significant (p < 0.0004) and that this occurs after a degree of rotation that is dependent on the pedicle length. The critical degree of rotation required to significantly affect blood flow is 30 degrees for each centimeter of pedicle length. The degree of rotation required to stop flow altogether is 45 degrees per unit length. Flow through the arteries was found to be inversely proportional to the length of the artery but was not affected by changes in the position of the artery provided there was not a rotational component. Tension of the pedicle did not influence flow in either a linear or rotated position. These results were verified in a clinical setting. This study supports that a 180-degree rotation of the internal mammary artery pedicle in any clinical setting will not alter blood flow. For rotations of 360 degrees or greater, however, the effect on flow becomes significant when this is 12 cm or less. Although flow is independent of linear pedicle deformity, as flow is inversely proportional to length, excess pedicle length is best avoided.
Authors:
R P Brown
Related Documents :
18845369 - Risk of hemodialysis graft thrombosis: analysis of monthly flow surveillance.
15172269 - Digital blood flow after radial artery harvest for coronary artery bypass grafting.
10933149 - Local blood flow regulation in transplanted rat pancreatic islets: influence of adenosi...
19050519 - A new model for studying the revascularization of skin grafts in vivo: the role of angi...
7622539 - Surface and blood-contacting properties of alkylsiloxane monolayers supported on silico...
3440729 - Thermodynamic correlates of hot tip laser angioplasty.
9068519 - Evaluation of left atrial appendage function by measurement of changes in flow velocity...
16878079 - Smokers have severely disturbed peripheral micro-circulation.
9869139 - Hemoglobin oxygenation of venous-perfused forearm flaps.
Publication Detail:
Type:  In Vitro; Journal Article    
Journal Detail:
Title:  The Annals of thoracic surgery     Volume:  59     ISSN:  0003-4975     ISO Abbreviation:  Ann. Thorac. Surg.     Publication Date:  1995 Feb 
Date Detail:
Created Date:  1995-03-09     Completed Date:  1995-03-09     Revised Date:  2006-11-15    
Medline Journal Info:
Nlm Unique ID:  15030100R     Medline TA:  Ann Thorac Surg     Country:  UNITED STATES    
Other Details:
Languages:  eng     Pagination:  416-8     Citation Subset:  AIM; IM    
Affiliation:
Alfred Hospital, Melbourne, Australia.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Blood Flow Velocity*
Humans
Internal Mammary-Coronary Artery Anastomosis / methods*
Mammary Arteries / physiology*

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Expression of Lewis-related antigen and prognosis in stage I non-small cell lung cancer.
Next Document:  The forgotten interleaflet triangles: a review of the surgical anatomy of the aortic valve.