Effect of airway diameter, suction catheters, and the bronchofiberscope on airflow in endotracheal and tracheostomy tubes.
MedLine Citation:
PMID:  1063116     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Pressure-flow relationships of an artificial airway-mechanical ventilator system were investigated. Endotracheal tubes varying from 7 to 9.5 mm. internal diameter and tracheostomy tubes from 7 to 10 mm. internal diameter were tested over flow-rates from 0.3 to 1.4 L. per second using a tidal volume of 500 ml. The effect of partial obstruction within these airways by suction catheters and the bronchofiberscope was examined. Depending on the internal diameter and the flow-rate, the driving pressure necessary to overcome the resistance of the tubes ranged from 5 to 20 cm. H2O. Partial obstruction of the artificial airways by suction catheters further increased this pressure. The introduction of the bronchofiberscope through an endotracheal tube of 7.5 mm. internal diameter, leaving an effective diameter of 4.9 mm., produced a driving pressure as high as 70 cm. H2O and reduced the flow rate to 50 per cent and the tidal volume to 80 per cent of its set value. Attention should be paid to duration of tracheobronchial suction while the patient is removed from the respirator since a high-grade resistance is created by passage of a suction catheter through an endotracheal tube. Bronchofiberscopy should be cautiously performed through cuffed artificial airways with at least 8 mm. internal diameter because the airway may be too comprised even if mechanical ventilatory assistance is employed.
Authors:
H Baier; R Begin; M A Sackner
Related Documents :
6349936 - Continuous positive airway pressure is beneficial in treatment of smoke inhalation.
9674466 - Sputum rheology changes in cystic fibrosis lung disease following two different types o...
3519566 - Effect of raised thoracic pressure and volume on 99mtc-dtpa clearance in humans.
484186 - Studies on intrapulmonary gas distribution in the normal subject. influence of anaesthe...
6184566 - Serum concentration and antihypertensive effect of slow-release verapamil.
8074216 - Relaxation responses of the human proximal stomach to distension during fasting and aft...
Publication Detail:
Type:  Journal Article; Research Support, U.S. Gov't, P.H.S.    
Journal Detail:
Title:  Heart & lung : the journal of critical care     Volume:  5     ISSN:  0147-9563     ISO Abbreviation:  Heart Lung     Publication Date:    1976 Mar-Apr
Date Detail:
Created Date:  1976-07-06     Completed Date:  1976-07-06     Revised Date:  2008-11-21    
Medline Journal Info:
Nlm Unique ID:  0330057     Medline TA:  Heart Lung     Country:  UNITED STATES    
Other Details:
Languages:  eng     Pagination:  235-8     Citation Subset:  IM    
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Bronchoscopes
Bronchoscopy*
Catheterization
Drainage / instrumentation*
Fiber Optic Technology
Humans
Intubation, Intratracheal / instrumentation*
Pulmonary Ventilation*
Tracheotomy
Ventilators, Mechanical

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Kleine-Levin syndrome. Female cases and catamneses
Next Document:  Electrolyte concentration in the hypertrophic salivary glands of incisor-amputated rats.