Effect of PEEP-valve placement on function of a home-care ventilator.
MedLine Citation:
PMID:  10145564     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
BACKGROUND: The addition of a PEEP valve to the circuit of a home-care ventilator like the Aequitron LP-6 can be viewed as a consumer modification of the system. We sought to determine the effect that such a modification would have on ventilator function. METHODS & MATERIALS: Part 1. We tested the effect of PEEP level and PEEP-valve position on volume delivered at the ventilator Y-adapter, over a range of tidal volumes. Part 2. We held tidal volume, frequency, and inspiratory time constant, and varied PEEP level and PEEP-valve position to test the effect of PEEP-valve position on pressures measured at the ventilator outlet, patient-Y, and within the exhalation-valve pressurization line. RESULTS: Conventional placement of the PEEP value (distal to, or 'after,' the exhalation valve) in the LP-6 ventilator circuit resulted in statistically significant and potentially clinically important decreases in the volumes delivered to the patient at some ventilator settings. Proximal placement of the PEEP valve (proximal to, or 'before,' the exhalation valve) resulted in consistent volumes delivered to the patient at all levels tested, without changing the ventilatory performance characteristics of the ventilator as reflected by pressure waveforms. CONCLUSION: We recommend that appropriate observations and measurements be made to verify system function before a home-care ventilator modified to provide PEEP is applied to the patient.
Authors:
J W Gietzen; J A Lund; J L Swegarden
Related Documents :
1889494 - Comparison of the effects of intravenous almitrine and positive end-expiratory pressure...
16179824 - Cardiac tamponade due to pneumopericardium.
8087114 - Volume-controlled ventilation and pressure-controlled inverse ratio ventilation: a comp...
2675704 - Effect of airway pressure on pericardial pressure.
1773504 - Contrasting hemodynamic effects of high oral calcium in genetic models of salt-sensitiv...
16211744 - Which is responsible for the haemodynamic response due to laryngoscopy and endotracheal...
Publication Detail:
Type:  Comparative Study; Journal Article    
Journal Detail:
Title:  Respiratory care     Volume:  36     ISSN:  0020-1324     ISO Abbreviation:  Respir Care     Publication Date:  1991 Oct 
Date Detail:
Created Date:  1992-01-24     Completed Date:  1992-01-24     Revised Date:  2007-11-15    
Medline Journal Info:
Nlm Unique ID:  7510357     Medline TA:  Respir Care     Country:  UNITED STATES    
Other Details:
Languages:  eng     Pagination:  1093-8     Citation Subset:  H    
Affiliation:
St Luke's Hospital-MeritCare, Fargo, ND 58122.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Evaluation Studies as Topic
Home Nursing / standards*
Humans
Positive-Pressure Respiration / instrumentation*
United States
Ventilators, Mechanical / standards*

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Capital PPS transition period affects timing differences.
Next Document:  Cost impact of metered dose inhalers vs small volume nebulizers in hospitalized patients: the Clevel...