Document Detail


The Effect of Intracranial Stent Implantation on the Curvature of the Cerebrovasculature.
MedLine Citation:
PMID:  22538075     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
BACKGROUND AND PURPOSE:Recently, the use of stents to assist in the coiling and repair of wide-neck aneurysms has been shown to be highly effective; however, the effect of these stents on the RC of the parent vessel has not been quantified. The purpose of this study was to quantify the effect of intracranial stenting on the RC of the implanted artery using 3D datasets.MATERIALS AND METHODS:Twenty-four patients receiving FDA-approved neurovascular stents to support coil embolization of brain aneurysms were chosen for this study. The stents were located in the ICA, ACA, or MCA. We analyzed C-arm rotational angiography and contrast-enhanced cone beam CT datasets before and after stent implantation, respectively, to ascertain changes in vessel curvature. The images were reconstructed, and the vessel centerline was extracted. From the centerline, the RC was calculated.RESULTS:The average implanted stent length was 25.4 ± 5.8 mm, with a pre-implantation RC of 7.1 ± 2.1 mm and a postimplantation RC of 10.7 ± 3.5 mm. This resulted in a 3.6 ± 2.7 mm change in the RC due to implantation (P < .0001), more than a 50% increase from the pre-implantation value. There was no difference in the change of RC for the different locations studied. The change in RC was not impacted by the extent of coil packing within the aneurysm.CONCLUSIONS:The implantation of neurovascular stents can be shown to have a large impact on the RC of the vessel. This will lead to a change in the local hemodynamics and flow pattern within the aneurysm.
Authors:
R M King; J-Y Chueh; I M J van der Bom; C F Silva; S L Carniato; G Spilberg; A K Wakhloo; M J Gounis
Related Documents :
441345 - After-loading transperineal iridium-192 wire implantation of the prostate.
22351785 - The effect of patch testing on surgical practices and outcomes in orthopedic patients w...
23790515 - Efficacy of the active middle-ear implant in patients with sensorineural hearing loss.
11121665 - Real-time optimized intraoperative dosimetry for prostate brachytherapy: a pilot study.
15162545 - Liver regional continuous chemotherapy: use of femoral or subclavian artery for percuta...
271725 - Tear strength of elastomeric impression materials.
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2012-4-26
Journal Detail:
Title:  AJNR. American journal of neuroradiology     Volume:  -     ISSN:  1936-959X     ISO Abbreviation:  -     Publication Date:  2012 Apr 
Date Detail:
Created Date:  2012-4-27     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  8003708     Medline TA:  AJNR Am J Neuroradiol     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Affiliation:
Department of Radiology, New England Center for Stroke Research, University of Massachusetts Medical School, Worcester, Massachusetts; and Research and Development, Stryker Neurovascular, Fremont, California.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  High-Resolution Diffusion-Weighted Imaging Increases Lesion Detectability in Patients with Transient...
Next Document:  Hemorrhage/Contrast Staining Areas after Mechanical Intra-Arterial Thrombectomy in Acute Ischemic St...