Document Detail


The Effect on Hemolysis of the Raceway Profile of Roller Pumps Used in Cardiopulmonary Bypass.
MedLine Citation:
PMID:  21266907     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
This study aims at the influence on hemolysis of the differences between the maximum and minimum amplitudes of pressure in the outlet of three roller pump models adjusted by dynamic calibration method. Tests were performed with silicone tubes (½ × 3/16 inches) in fluid analogous to blood and fresh bovine blood from slaughterhouse. Tests with analogous solution to blood were performed varying the dynamic calibration pressure between 78 and 500 mm Hg. Tests with fresh bovine blood were performed with the three pumps simultaneously, and pressure differences and free hemoglobin in the plasma were measured during 360 minutes. Tests with both analogous solution to blood and fresh bovine blood showed differences of mean pressures of pump 2 related to pumps 1 and 3 (p < 0.01). The different models of roller pumps analyzed presented differences in pressure amplitudes (p < 0.01) and hemolysis (p < 0.01) adjusted for the same dynamic calibration pressure. Raceway profile of pump 2 resulted in smaller pressure amplitude, implying lower hemolysis rate compared with pumps 1 and 3.
Authors:
Francisco Ubaldo Vieira; Eduardo Tavares Costa; Reinaldo Wilson Vieira; Nilson Antunes; Orlando Petrucci; Pedro Paulo de Oliveira
Related Documents :
10830237 - Beneficial effect of additional cardioplegia flush during hypothermic static cardiac pr...
6409447 - Myocardial salvage by intravenous nitroglycerin in conscious dogs: loss of beneficial e...
23607687 - Evaluation of intra-abdominal pressure in horses that crib.
24955577 - The value of a bp determination method using a novel non-invasive bp device against the...
23958407 - Effects of calcium and vitamin d supplementation on blood pressure and serum lipids and...
9349947 - Inverse correlation between endothelin-1-induced peripheral microvascular vasoconstrict...
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2011-1-24
Journal Detail:
Title:  ASAIO journal (American Society for Artificial Internal Organs : 1992)     Volume:  -     ISSN:  1538-943X     ISO Abbreviation:  -     Publication Date:  2011 Jan 
Date Detail:
Created Date:  2011-1-26     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  9204109     Medline TA:  ASAIO J     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Affiliation:
From the *Nucleus of Medicine and Experimental Surgery, School of Medical Sciences, and †Center for Biomedical Engineering, University of Campinas (UNICAMP), Campinas, São Paulo, Brazil.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Do miniaturized extracorporeal circuits confer significant clinical benefit without compromising saf...
Next Document:  Factors associated with decreased kidney function in HIV-infected adults enrolled in the MTCT-Plus I...