Document Detail

Echocardiography and assessing fluid responsiveness: acoustic quantification again into the picture?
Jump to Full Text
MedLine Citation:
PMID:  17274831     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Accurate identification of fluid responsiveness has become an important issue in critically ill patients. Pulse pressure and stroke volume variation have been shown to be reliable predictors of fluid responsiveness. Apart from these two valuable techniques, echo-Doppler offers an interesting alternative for estimating the adequacy of filling. Acoustic quantification is a high-tech tool for delineating the blood-tissue interface on-screen in real time. Cannesson and coworkers utilized this technique in ventilated patients to assess stroke area changes, with the intention being to predict fluid responsiveness.
Authors:
Jan Poelaert; Carl Roosens
Publication Detail:
Type:  Comment; Journal Article; Research Support, Non-U.S. Gov't    
Journal Detail:
Title:  Critical care (London, England)     Volume:  11     ISSN:  1466-609X     ISO Abbreviation:  Crit Care     Publication Date:  2007  
Date Detail:
Created Date:  2007-04-17     Completed Date:  2007-05-11     Revised Date:  2009-11-18    
Medline Journal Info:
Nlm Unique ID:  9801902     Medline TA:  Crit Care     Country:  England    
Other Details:
Languages:  eng     Pagination:  105     Citation Subset:  IM    
Affiliation:
University Hospital Ghent, Department of Intensive Care Medicine and Cardiac Anaesthesia, De Pintelaan, Gent, Belgium. jan.poelaert@ugent.be
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Acoustics
Blood Pressure
Critical Illness*
Echocardiography, Transesophageal*
Humans
Respiration
Stroke Volume*
Ventricular Function, Left
Comments/Corrections
Comment On:
Crit Care. 2006;10(6):R171   [PMID:  17163985 ]

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine

Full Text
Journal Information
Journal ID (nlm-ta): Crit Care
ISSN: 1364-8535
ISSN: 1466-609X
Publisher: BioMed Central
Article Information
Download PDF
Copyright ? 2007 BioMed Central Ltd
Print publication date: Year: 2007
Electronic publication date: Day: 23 Month: 1 Year: 2007
Volume: 11 Issue: 1
First Page: 105 Last Page: 105
ID: 2151869
Publisher Id: cc5140
PubMed Id: 17274831
DOI: 10.1186/cc5140

Echocardiography and assessing fluid responsiveness: acoustic quantification again into the picture?
Jan Poelaert1 Email: jan.poelaert@ugent.be
Carl Roosens1
1University Hospital Ghent, Department of Intensive Care Medicine and Cardiac Anaesthesia, De Pintelaan, B-9000 Gent, Belgium

Optimization of haemodynamics in critically ill patients necessitates a critical balance between cardiac preload, afterload and myocardial performance. In this context, assessment of fluid responsiveness remains difficult, especially in haemodynamically unstable patients. Many researchers have invested their experience in developing reproducible methods to predict optimal preload safely and adequately. Furthermore, echocardiography may be helpful in estimating fluid responsiveness [1]. Alterations in intra-thoracic pressures during mechanical ventilation are known to induce cyclic variations in preloading conditions of the right and left ventricles, resulting in discrete changes in stroke volume and hence in arterial pressure [2]. Significant ventilation-induced undulations in the arterial pressure tracing are clinically related to the presence of hypovolaemia, both in patients with preserved and in those with decreased left ventricular (LV) function [3]. In septic shock patients, analysis of stroke volume variation has been shown to indicate most accurately the presence of fluid responsiveness.

Echocardiography and echo-Doppler have been demonstrated to be an invaluable tool in the haemodynamic management of the critically ill, either through a transthoracic [4] or transoesophageal [5] approach. Estimation of volume status in ventilated intensive care unit (ICU) patients has also been a focus for many ICU echocardiographers. Assessment of the collapsibility of the inferior or superior [6] caval vein is a relatively simple method to identify the presence of fluid responsiveness, although it is strongly influenced by right ventricular function. Echo-Doppler was shown to be a good alternative to pressures obtained by invasive means in demonstrating the presence of fluid responsiveness. In a graded haemorrhagic rabbit model, Slama and coworkers [7] found that ventilation-induced transaortic flow variation could be used in place of invasive pressure variation, underlining the physiological link between pressure and flow [8].

Acoustic quantification (AQ) was introduced in the early 1990s, with the intention being to delineate ? both on-screen and in real time ? the blood-tissue interface at the level of the various cavities of the heart and great vessels [9]. In the construction of pressure-volume loops, AQ has mostly been exploited as a clever tool to replace the invasive assessment of the volume component [10] in the estimation of end-systolic elastance. Despite such an appealing application of this investigational tool, the transition toward its integration into clinical practice is not so easy. Several drawbacks must be acknowledged, the most important being the fact that the smallest of changes in transoesophageal echo (TOE) probe position relative to the left ventricle can significantly alter estimates of LV contractility. It is therefore more appealing to apply this technology to assessment of cavities that are less mobile (or that can be rendered less mobile). Our research group showed an intriguing correlation between AQ obtained aortic contour variations and the derived afterload parameters at one side and the Langewouters' model at the other [11].

In the previous issue of Critical Care, Cannesson and coworkers [1] applied the AQ technique to assess stroke area changes in real time in mechanically ventilated cardiac surgical patients with preserved LV function, as a representative index of fluid responsiveness. In this interesting study, which included a relatively small number of patients, Cannesson and coworkers nicely circumvented the problems associated with change in TOE probe position with respect to the LV short axis by utilizing passive leg raising (trunk lowering from 45? to 0?).

However, as with previous studies using AQ, this investigation identified several issues that should be kept in mind before this technique may be routinely implemented to assess fluid responsiveness. First, despite the careful implementation of passive leg raising, a small shift or displacement of the TOE probes in relation to the LV short axis could distort the findings significantly. The analysis of endocardial motion can be confounded if it is applied to patients with segmental wall motion abnormalities [12]. Second, inherently linked to the structure of the myocardial muscle fibres, LV rotations and torsions could be present, which again could interfere with AQ-based assessment. Third, in a subset of coronary patients, a transient increase in load by leg elevation results in a decrease in dP/dtmax and a major increase in LV end-diastolic pressure. This impairment is linked to deficient length-dependent regulation of myocardial function [13]. Finally, echo-Doppler provides discontinuous information, which is in contrast to routinely available haemodynamic monitors.

De Backer and coworkers [14] showed that pulse pressure variation was a reliable predictor of fluid responsiveness only if tidal volume was more than 8 ml/kg. Further investigation is necessary to reveal whether the observations reported by Cannesson and coworkers [1] are also valid in patients ventilated with tidal volumes of less than 8 ml/kg and a higher level of positive end-expiratory pressure (as is the case for patients with acute respiratory distress syndrome). Although dynamic indices of fluid responsiveness are evidently superior to static markers, Doppler echocardiography provides a variety of bedside solutions to problems relating to hypo-volaemia in a relatively noninvasive and dynamic manner. The great strength of this tool lies in its power to add supplementary information regarding contractility and afterloading conditions in a direct, comprehensible and physiological manner at the bedside.


Abbreviations

AQ = acoustic quantification; ICU = intensive care unit; LV = left ventricular; TOE = transoesophageal echo.


Competing interests

The authors declare that they have no competing interests.


Acknowledgements

Work conducted by the authors is supported by an unrestricted grant from the International Research Centre of the Ghent University, Gent, Belgium.


References
Cannesson M,Slieker J,Desebbe O,Farhat F,Bastien O,Lehot JJ. Prediction of fluid responsiveness using respiratory variations in left ventricular stroke area by transesophageal echocardiographic automated border detection in mechanically ventilated patientsCrit Care 2006;10:R171. [pmid: 17163985] [doi: 10.1186/cc5123]
Perel A,Pizov R,Cotev S. Systolic blood pressure variation is a sensitive indicator of hypovolaemia in ventilated dogs subjected to graded hemorrhageAnesthesiology 1987;67:498–502. [pmid: 3310740] [doi: 10.1097/00000542-198710000-00009]
Reuter DA,Kirchner A,Felbinger TW,Weis FC,Kilger E,Lamm P,Goetz AE. Usefulness of left ventricular stroke volume variation to assess fluid responsiveness in patients with reduced cardiac functionCrit Care Med 2003;31:1399–1404. [pmid: 12771609] [doi: 10.1097/01.CCM.0000059442.37548.E1]
Vignon P,Mentec H,Terr? S,Gastinne H,Gu?ret P,Lemaire F. Diagnostic accuracy and therapeutic impact of transthoracic and transesophageal echocardiography in mechanically ventilated patients in the ICUChest 1994;106:1829–1834. [pmid: 7988209]
Poelaert JI,Trouerbach J,De Buyzere M,Everaert J,Colardyn FA. Evaluation of transesophageal echocardiography as a diagnostic and therapeutic aid in a critical care settingChest 1995;107:774–779. [pmid: 7874952]
Vieillard-Baron A,Chergui K,Rabiller A,Peyrouset O,Page B,Beauchet A,Jardin F. Superior vena caval collapsibility as a gauge of volume status in ventilated septic patientsIntensive Care Med 2004;30:1734–1739. [pmid: 15375649]
Slama M,Masson H,Teboul JL,Arnout ML,Susic D,Frohlich E,Andrejak M. Respiratory variations of aortic VTI: a new index of hypovolemia and fluid responsivenessAm J Physiol Heart Circ Physiol 2002;283:H1729–H1733. [pmid: 12234829]
Poelaert JI,Schupfer G. Hemodynamic monitoring utilizing transesophageal echocardiography: the relationships among pressure, flow, and functionChest 2005;127:379–390. [pmid: 15654003] [doi: 10.1378/chest.127.1.379]
Cahalan M,Ionescu P,Melton H,Adler S,Kee L,Schiller N. Automated real-time analysis of intraoperative transesophageal echocardiogramsAnesthesiology 1993;78:477–484. [pmid: 8457048]
Gorcsan J,Gasior T,Mandarino W,Deneault L,Hattler B,Pinsky M. On-line estimation of changes in left ventricular stroke volume by transesophageal echocardiographic automated border detection in patients undergoing coronary artery bypass graftingAm J Cardiol 1993;72:721–727. [pmid: 8249852] [doi: 10.1016/0002-9149(93)90892-G]
Heerman JR,Segers P,Roosens CD,Gasthuys F,Verdonck PR,Poelaert JI. Echocardiographic assessment of aortic elastic properties with automated border detection in an ICU: in vivo application of the arctangent Langewouters modelAm J Physiol Heart Circ Physiol 2005;288:H2504–H2511. [pmid: 15604135] [doi: 10.1152/ajpheart.00368.2004]
Lang RM,Vignon P,Weinert L,Bednarz J,Korcarz C,Sandelski J,Koch R,Prater D,Mor-Avi V. Echocardiographic quantification of regional left ventricular wall motion with color kinesisCirculation 1996;93:1877–1885. [pmid: 8635267]
De Hert S,Vander Linden P,Ten Broecke P,De Mulder P,Rodrigus I,Adriaensen H. Assessment of length-dependent regulation of myocardial function in coronary surgery patients using transmitral flow velocity patternsAnesthesiology 2000;93:374–381. [pmid: 10910486] [doi: 10.1097/00000542-200008000-00015]
De Backer D,Heenen S,Piagnerelli M,Koch M,Vincent JL. Pulse pressure variations to predict fluid responsiveness: influence of tidal volumeIntensive Care Med 2005;31:517–523. [pmid: 15754196] [doi: 10.1007/s00134-005-2586-4]

Article Categories:
  • Commentary


Previous Document:  The use of mechanical restraint and seclusion in patients with schizophrenia: a comparison of the pr...
Next Document:  Obesity hormone leptin: a new target in breast cancer?