Echocardiographic Evaluation of a TASER-X26 Application in the Ideal Human Cardiac Axis.
MedLine Citation:
PMID:  18699824     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
Objectives: TASER electronic control devices (ECDs) are used by law enforcement to subdue aggressive persons. Some deaths temporally proximate to their use have occurred. There is speculation that these devices can cause dangerous cardiac rhythms. Swine research supports this hypothesis and has reported significant tachyarrhythmias. It is not known if this occurs in humans. The objective of this study was to determine the occurrence of tachyarrhythmias in human subjects subjected to an ECD application. Methods: This was a prospective, nonblinded study. Human volunteers underwent limited echocardiography before, during, and after a 10-second TASER X26 ECD application with preplaced thoracic electrodes positioned in the upper right sternal border and the cardiac apex. Images were analyzed using M-mode through the anterior leaflet of the mitral valve for evidence of arrhythmia. Heart rate (HR) and the presence of sinus rhythm were determined. Data were analyzed using descriptive statistics. Results: A total of 34 subjects were enrolled. There were no adverse events reported. The mean HR prior to starting the event was 108.7 beats/min (range 65 to 146 beats/min, 95% CI = 101.0 to 116.4 beats/min). During the ECD exposure, the mean HR was 120.1 beats/min (range 70 to 158 beats/min, 95% CI = 112.2 to 128.0 beats/min) and a mean of 94.1 beats/min (range 55 to 121 beats/min, 95% CI = 88.4 to 99.7 beats/min) at 1 minute after ECD exposure. Sinus rhythm was clearly demonstrated in 21 (61.7%) subjects during ECD exposure (mean HR 121.4 beats/min; range 75 to 158 beats/min, 95% CI = 111.5 to 131.4). Sinus rhythm was not clearly demonstrated in 12 subjects due to movement artifact (mean HR 117.8 beats/min, range 70 to 152 beats/min, 95% CI = 102.8 to 132.8 beats/min). Conclusions: A 10-second ECD exposure in an ideal cardiac axis application did not demonstrate concerning tachyarrhythmias using human models. The swine model may have limitations when evaluating ECD technology.
Authors:
Jeffrey D Ho; Donald M Dawes; Robert F Reardon; Anne L Lapine; Benjamin J Dolan; Erik J Lundin; James R Miner
Related Documents :
2528654 - Impact of left ventricular hypertrophy on survival in end-stage renal disease.
15177234 - Ace inhibitors increase type iii collagen synthesis: a potential explanation for reduct...
22296564 - Prinzmetal angina in the differential diagnosis of syncope.
7799494 - Risk stratification in unstable angina. prospective validation of the braunwald classif...
8005134 - Double ventricular responses during extrastimulation of atrioventricular nodal reentran...
21095364 - Arrhythmogenic left ventricular cardiomyopathy associated with noncompaction.
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2008-8-10
Journal Detail:
Title:  Academic emergency medicine : official journal of the Society for Academic Emergency Medicine     Volume:  -     ISSN:  1553-2712     ISO Abbreviation:  Acad Emerg Med     Publication Date:  2008 Aug 
Date Detail:
Created Date:  2008-8-13     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  9418450     Medline TA:  Acad Emerg Med     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Affiliation:
Department of Emergency Medicine, Hennepin County Medical Center, Minneapolis, MN, USA.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Direct Comparison of the Diagnostic Accuracy of Fifty Protein Biological Markers of Pulmonary Emboli...
Next Document:  The Effect of Emergency Department Crowding on Patient Satisfaction for Admitted Patients.