Document Detail


Early experience with the Bard XT stent.
MedLine Citation:
PMID:  9863763     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
The Bard XT stent is a new generation balloon expandable intracoronary stent. It has several unique design advantages. Between October 1996 and November 1997, 127 Bard XT stents of various length were deployed in 93 patients with 109 lesions. According to the American College of Cardiology (ACC) and American Heart Association (AHA) classifications 7 lesions were type A, 38 were type B1, 43 were type B2 and 21 were type C [Ellis et al.: Circulation 82:1193-1202, 1990]. Stent delivery was successful in 98% of attempts. Angiographic success was achieved in 98% of 109 lesions. Procedural success was achieved in 94% of 93 patients. Minimal luminal diameter (MLD) increased from 0.91+/-0.34 mm to 3.03+/-0.44 mm and percentage diameter stenosis reduced from 69.1+/-11.07 to 9.96+/-6.81. Complications occurred in four patients. One patient had intracranial hemorrhage, one patient had subacute thrombosis and two patients died postprocedure. Patients were followed for a period of 1 to 14 months (average 7+/-4 months) for major cardiac events and clinical restenosis. The Bard XT stent is a user-friendly device which provided excellent angiographic results and short-term clinical outcome in selected cases. Further study is required to evaluate effects on restenosis.
Authors:
H Ravat; A Cannon
Related Documents :
10973333 - Clinical and angiographic results with the multi-linkª coronary stent system Ñ the we...
15882713 - Routine insertion of ureteral stent in live-donor renal transplantation: is it worthwhile?
24004813 - Comparison between the new gore septal and amplatzer devices for transcatheter closure ...
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Catheterization and cardiovascular diagnosis     Volume:  45     ISSN:  0098-6569     ISO Abbreviation:  Cathet Cardiovasc Diagn     Publication Date:  1998 Dec 
Date Detail:
Created Date:  1999-02-25     Completed Date:  1999-02-25     Revised Date:  2004-11-17    
Medline Journal Info:
Nlm Unique ID:  7508512     Medline TA:  Cathet Cardiovasc Diagn     Country:  UNITED STATES    
Other Details:
Languages:  eng     Pagination:  462-70     Citation Subset:  IM    
Affiliation:
Department of Cardiology, Townsville General Hospital, Queensland, Australia.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Adult
Aged
Aged, 80 and over
Angina Pectoris / radiography,  therapy*
Angina, Unstable / radiography,  therapy
Angioplasty, Transluminal, Percutaneous Coronary*
Coronary Angiography
Female
Humans
Male
Middle Aged
Prosthesis Design
Retrospective Studies
Stents*

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Protection of side-branches in coronary lesions with a new stent design.
Next Document:  Heat stress, even extreme, does not induce penetration of pyridostigmine into the brain of guinea pi...