| Dynamic cine-computed tomography angiography imaging of standard and fenestrated endografts: differing effects on renal artery motion. | |
| | |
MedLine Citation:
|
PMID: 18238864 Owner: NLM Status: MEDLINE |
Abstract/OtherAbstract:
|
Different endograft configurations (fenestrated, transrenal, infrarenal) may varyingly affect aortic side branch movement. Renal artery motion was evaluated with 64-slice dynamic cine-computed tomography angiography before and after endovascular aneurysm repair in 16 patients (46 renal arteries). Center-of-mass displacement of the renals was determined per heartbeat for before repair for 3 different endografts; differences were compared, with significance at P < 0.5. Preoperative renal artery motion is significant (1.2 [SD 0.5] mm, range, 0.6-2.). Neither transrenal nor infrarenal endografts alter renal artery motion compared with before repair (P < .05). Renal artery motion after fenestrated endovascular repair with renal stents reduces motion to 25% of the preoperative value (0.3 [SD, 0.1] mm, range, 0.2-0.5 mm; P = .01). Endograft implantation without stented side branches does not change renal artery motion, potentially allowing significant movement of the renal artery relative to the fenestration. Routine stenting of fenestrations limits postoperative renal artery motion to 0.3 mm, thereby preventing significant branch movement in relation the fenestration. |
| | |
Authors:
|
Bart E Muhs; Koen L Vincken; Arno Teutelink; Eric L G Verhoeven; Matthias Prokop; Frans L Moll; Hence J M Verhagen |
Related Documents
:
|
7302214 - Ablation of renal tumors with absolute ethanol: a new technique. 11383914 - Conn's syndrome and bilateral renal artery stenosis in the presence of multiple renal a... 19328974 - Single or double arteries in the remnant kidney after donation: influence on the long-t... 9972894 - Aneurysms of the supra-aortic trunks in takayasu's disease. report of two cases. 17021444 - Anesthesia for pulmonary stent insertion. 7436004 - An anomalous ophthalmic artery arising from the middle meningeal artery. |
Publication Detail:
|
Type: Journal Article |
Journal Detail:
|
Title: Vascular and endovascular surgery Volume: 42 ISSN: 1538-5744 ISO Abbreviation: Vasc Endovascular Surg Publication Date: 2008 Feb-Mar |
Date Detail:
|
Created Date: 2008-02-01 Completed Date: 2008-05-13 Revised Date: - |
Medline Journal Info:
|
Nlm Unique ID: 101136421 Medline TA: Vasc Endovascular Surg Country: United States |
Other Details:
|
Languages: eng Pagination: 25-31 Citation Subset: IM |
Affiliation:
|
Department of Vascular Surgery, University Medical Center Utrecht, Utrecht, The Netherlands. |
Export Citation:
|
APA/MLA Format Download EndNote Download BibTex |
| MeSH Terms | |
Descriptor/Qualifier:
|
Analysis of Variance Angiography / methods* Aortic Aneurysm, Abdominal / surgery* Blood Vessel Prosthesis Implantation* Contrast Media Feasibility Studies Humans Iopamidol / analogs & derivatives, diagnostic use Motion Prosthesis Design Radiographic Image Interpretation, Computer-Assisted Renal Artery / physiology*, radiography* Stents* Tomography, X-Ray Computed* Vascular Patency Video Recording |
| Chemical | |
Reg. No./Substance:
|
0/Contrast Media; 62883-00-5/Iopamidol; 78649-41-9/iomeprol |