Document Detail


Durability evaluation of a friction couple intended for implantological stabilization of complete dentures.
MedLine Citation:
PMID:  19152467     Owner:  NLM     Status:  In-Process    
Abstract/OtherAbstract:
The paper presents the results of the study of the titanium implant-elastomeric membrane attachment, conducted from the point of view of potential utilization of the results in forecasting the durability of retention elements representing a new solution of dentures based on implants. The examination was carried out using a device designed by the author, which allowed the simulation of the process of inserting and removing dentures. Titanium counter specimens, simulating implants, were subjected to surface modification through their sandblasting with 350 um and 500 um abrasives, so as to diversify their roughness. The elastomeric membranes constituting a retention element of the attachment were made of a silicone material, Molloplast B. The influence of the number of cycles (one cycle meaning one insertion and removal of a denture) on the attachment's retention force was studied. In order to better reflect the natural conditions, the device was equipped with a chamber which made it possible to perform the examination in an artificial saliva environment. The study has shown that the application of the polymer material Molloplast B for constructing the new type retention elements of dentures based on implants ensures practically constant values of the attachment's retention force in the required 6-month utilization period. After the time of denture usage, being eight times longer than originally assumed, the loss of retention force does not exceed 43% in any of the attachments investigated and the retention force values still allow the attachments to operate, although their effectiveness is partly reduced.
Authors:
Grzegorz Chladek
Related Documents :
2490587 - Clinical evaluation of a new resilient denture liner in long-term use.
9744237 - How well are complete dentures copied?
9487807 - Gnathosonic study of occlusion in patients wearing complete dentures.
2074597 - Immediate fixed interim prostheses supported by two-stage threaded implants: methodolog...
18199267 - Efficiency assessment of a swift method to enhance substandard viability ram ejaculates.
11336367 - Composite implant composed of hydroxyapatite and bone morphogenetic protein in the heal...
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Acta of bioengineering and biomechanics / Wrocław University of Technology     Volume:  10     ISSN:  1509-409X     ISO Abbreviation:  Acta Bioeng Biomech     Publication Date:  2008  
Date Detail:
Created Date:  2009-01-20     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  101194794     Medline TA:  Acta Bioeng Biomech     Country:  Poland    
Other Details:
Languages:  eng     Pagination:  7-12     Citation Subset:  IM    
Affiliation:
Department of Mechanics of Materials, Silesian University of Technology, Katowice, Poland. chladek@interia.pl
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Testing the stability of the polyethylene acetabulum cemented on a frozen bone graft substrate on a ...
Next Document:  Influence of tongue activity on lower complete denture retention under biting forces.