Dual chamber pacing with a single lead system: initial clinical results.
MedLine Citation:
PMID:  8945039     Owner:  NLM     Status:  MEDLINE    
A new mode of biphasic pacing was used in 26 patients to assess the feasibility of atrial pacing by means of the floating atrial ring electrodes of a single lead VDD permanent pacing system. During implantation, atrial pacing was possible in 25 patients with a 1-ms total pulse duration, a mean atrial threshold of 1.70 +/- 0.60 V (range, 0.6-3.0), and a mean diaphragmatic threshold of 6.7 +/- 2.5 V (range, 2.5-10.0). At 3 months, the atrial threshold had increased beyond 4.8 V in three patients. In the 22 other patients, the mean atrial threshold was 2.2 +/- 0.5 V (range, 1.50-3.50) in the supine position and 2.5 +/- 0.8 V (range, 1.5-4.8) in the sitting position. Stable atrial capture without diaphragmatic stimulation was achieved in 76% of patients.
J L Rey; F el Ghelbazouri; C Tribouilloy
Related Documents :
17963339 - The relationship between the left atrial volume and the maximum p-wave and p-wave dispe...
8404169 - Unusual clinical presentations of secundum atrial septal defect.
1701539 - Relation between spontaneous atrial fibrillation and atrial vulnerability in patients w...
7814159 - Clinical profile and natural history of ebstein's anomaly of tricuspid valve.
9616849 - Evaluation of mean right atrial pressure by two-dimensional and doppler echocardiograph...
365429 - Acebutolol in supraventricular arrhythmias.
6354419 - Clinical trials and drug toxicity in the elderly. the experience of the eastern coopera...
2537799 - Serum levels of c-reactive protein in patients with pulmonary tuberculosis and malignan...
7290729 - Post-traumatic acute anterior spinal cord syndrome.
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Pacing and clinical electrophysiology : PACE     Volume:  19     ISSN:  0147-8389     ISO Abbreviation:  Pacing Clin Electrophysiol     Publication Date:  1996 Nov 
Date Detail:
Created Date:  1997-03-06     Completed Date:  1997-03-06     Revised Date:  2004-11-17    
Medline Journal Info:
Nlm Unique ID:  7803944     Medline TA:  Pacing Clin Electrophysiol     Country:  UNITED STATES    
Other Details:
Languages:  eng     Pagination:  1777-9     Citation Subset:  IM    
Cardiology Department, University Hospital, Amiens, France.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Aged, 80 and over
Atrial Function
Cardiac Pacing, Artificial / methods*
Diaphragm / physiology
Electric Stimulation
Equipment Design
Feasibility Studies
Follow-Up Studies
Middle Aged
Pacemaker, Artificial*
Supine Position

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine

Previous Document:  Evolution of atrial signals from a single lead VDD pacemaker. AddVent European Multicentre Study Gro...
Next Document:  Optimized standby rate reduces the ventricular rate variability in pacemaker patients with atrial fi...