Dual chamber arrhythmia detection in the implantable cardioverter defibrillator.
MedLine Citation:
PMID:  11059974     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
INTRODUCTION: Dual chamber implantable cardioverter defibrillator (ICD) technology extended ICD therapy to more than termination of hemodynamically unstable ventricular tachyarrhythmias. It created the basis for dual chamber arrhythmia management in which dependable detection is important for treatment and prevention of both ventricular and atrial arrhythmias. METHODS AND RESULTS: Dual chamber detection algorithms were investigated in two Medtronic dual chamber ICDs: the 7250 Jewel AF (33 patients) and the 7271 Gem DR (31 patients). Both ICDs use the same PR Logic algorithm to interpret tachycardia as ventricular tachycardia (VT), supraventricular tachycardia (SVT), or dual (VT+ SVT). The accuracy of dual chamber detection was studied in 310 of 1,367 spontaneously occurring tachycardias in which rate criterion only was not sufficient for arrhythmia diagnosis. In 78 episodes there was a double tachycardia, in 223 episodes SVT was detected in the VT or ventricular fibrillation zone, and in 9 episodes arrhythmia was detected outside the boundaries of the PR Logic functioning. In 100% of double tachycardias the VT was correctly diagnosed and received priority treatment. SVT was seen in 59 (19%) episodes diagnosed as VT. The causes of inappropriate detection were (1) algorithm failure (inability to fulfill the PR<RP condition in atrial tachyarrhythmias with 1:1 AV conduction, and far-field R wave sensing intermittently present during sinus tachycardia); (2) programming settings (atrial fibrillation/atrial flutter with ventricular rate above the SVT limit); and (3) algorithm limitations (atrial tachycardia with ventricular rate around the shortest programmable SVT limit and SVT redetection following VT therapy). Programming measures improved detection ability in 13 of 59 of inappropriately detected arrhythmias. CONCLUSION: Dual chamber detection algorithms evaluated in a subset of diagnostically difficult arrhythmias allow safe detection of double tachycardias but require further extension and programmability to improve VT:SVT discrimination rules.
Authors:
B Dijkman; H J Wellens
Related Documents :
6475774 - Long-term reproducibility of responses to programmed cardiac stimulation in spontaneous...
6883404 - Effects of duration of ventricular fibrillation and heart massage on haemodynamic respo...
20384654 - Electroanatomical mapping-guided endocardial and epicardial ablation of sustained ventr...
1735154 - Incidence and mechanism of interruption of reentrant ventricular tachycardia with rapid...
11753464 - Diagnosis of haemodynamically significant patent ductus arteriosus in neonates-- is the...
12408264 - The electromechanical effects of pacing at different sites within the right atrium.
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Journal of cardiovascular electrophysiology     Volume:  11     ISSN:  1045-3873     ISO Abbreviation:  J. Cardiovasc. Electrophysiol.     Publication Date:  2000 Oct 
Date Detail:
Created Date:  2001-02-07     Completed Date:  2001-02-08     Revised Date:  2007-11-15    
Medline Journal Info:
Nlm Unique ID:  9010756     Medline TA:  J Cardiovasc Electrophysiol     Country:  UNITED STATES    
Other Details:
Languages:  eng     Pagination:  1105-15     Citation Subset:  IM    
Affiliation:
Department of Cardiology, Academic Hospital Maastricht, The Netherlands. b.dijkman@cardio.azm.nl
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Adult
Aged
Algorithms
Arrhythmias, Cardiac / diagnosis*
Defibrillators, Implantable*
Humans
Middle Aged
Ventricular Fibrillation / diagnosis
Comments/Corrections
Comment In:
J Cardiovasc Electrophysiol. 2000 Oct;11(10):1116-8   [PMID:  11059975 ]

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Radiofrequency ablation of idiopathic left ventricular tachycardia at the site of earliest activatio...
Next Document:  Laplacian electrograms and the interpretation of complex ventricular activation patterns during vent...