Dose uncertainty due to aperture effects in dynamic fields.
MedLine Citation:
PMID:  16898444     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Dosimetry of intensity modulated radiation therapy requires accurate modeling of the beamlets that comprise each treatment segment. Planning systems such as Varian Eclipse and Philips Pinnacle recommend measuring dose distributions and output factors for fields as small as possible, generally down to at least 2 x 2 cm2. Conventionally, we perform these measurements for regular fields, defined by the secondary collimators. In practice, it is the multileaf collimation system (MLC) that defines the intensity map and provides dynamic dose modulation in either a moving window or segmented step-and-shoot mode. For this review we have only considered the latter delivery mode. Using this method, we have studied aperture motion effects on the dynamic collimator scatter (S(c)), total scatter (S(c,p)), and phantom scatter (S(p)) factors for various combinations of collimator settings (4 x 4-14 x 40 cm2) and dynamically stepped leaf gaps (0.1 to 1.0 cm) in comparison with those for static field factors. For two different Varian linear accelerators, we found similar results in a systematic dependence of collimator scatter on gap width and collimator setting. As the gap increases from 0.1 to 1.0 cm the dynamic collimator scatter factors converge from a maximum difference of about 30% toward the static field values. At the same time, there is no measurable difference between dynamic field phantom scatter factors and those conventionally obtained for static fields. Second, we evaluated the two planning systems as to how well they account for collimator scatter by attempting to mimic the dynamic apertures used above by planning and measuring dose distributions to several small, cylindrical targets for a similar range of fixed collimator settings. We found that the ratio of measured-to-planned doses as a function of target size were similar to the measured, dynamic S(c) data for the Varian Eclipse planning system, indicating underestimation of dose for targets smaller than 1 cm diameter, but were close to unity for the Philips Pinnacle system, suggestive of the underlying differences in the dose calculation algorithms. We discuss the measurements and results and potential impact on the dosimetry of small clinical targets.
Authors:
P D Higgins; P Alaei
Related Documents :
10514344 - Role of baseline parameters in determining indirect pharmacodynamic responses.
21406754 - Quantum criticality in inter-band superconductors.
8497224 - Dosimetry of large wedged high-energy photon beams.
6700554 - A model to generate beam profiles of the varian clinac 4 for three-dimensional dose cal...
15616834 - Comfa, hqsar and molecular docking studies of butitaxel analogues with beta-tubulin.
24103984 - Design and demonstration of a colorless wdm-ofdma pon system architecture achieving sym...
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Medical physics     Volume:  33     ISSN:  0094-2405     ISO Abbreviation:  Med Phys     Publication Date:  2006 Jul 
Date Detail:
Created Date:  2006-08-10     Completed Date:  2006-12-07     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  0425746     Medline TA:  Med Phys     Country:  United States    
Other Details:
Languages:  eng     Pagination:  2418-25     Citation Subset:  IM    
Affiliation:
Department of Therapeutic Radiology-Radiation Oncology, University of Minnesota, Minneapolis, Minnesota 55455, USA. higgi010@umn.edu
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Air
Algorithms
Particle Accelerators
Phantoms, Imaging
Radiometry / methods*
Radiotherapy Dosage
Radiotherapy Planning, Computer-Assisted / methods*
Reproducibility of Results
Scattering, Radiation
Uncertainty
Water / chemistry
X-Ray Film
Chemical
Reg. No./Substance:
7732-18-5/Water

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Automated localization of implanted seeds in 3D TRUS images used for prostate brachytherapy.
Next Document:  A Monte Carlo based three-dimensional dose reconstruction method derived from portal dose images.