Doppler measurement of cardiac output across prosthetic mitral valves.
MedLine Citation:
PMID:  2325355     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
In 46 patients with a normal functioning mitral valve prosthesis (15 St. Jude, 19 Medtronic Hall, 12 Hancock) cardiac output was measured by pulsed Doppler echocardiography across the valve prosthesis. Simultaneously cardiac output was determined by thermodilution or pulsed Doppler echocardiography in the left ventricular outflow tract (2.8 l/min-9.5 l/min). The prosthetic valve area was calculated using the pressure half-time method. Cardiac output was calculated by multiplying time-velocity integrals with the mitral valve area. Cardiac output measurements across the mitral prosthesis correlated significantly with thermodilution (r = 0.96, SEE = 0.400 l/min) and pulsed Doppler echocardiography flow measurements in the left ventricular outflow tract (r = 0.82, SEE = 0.679 l/min). The mean percent error of the Doppler transmitral flow measurement was 10.8%. Doppler transmitral flow underestimated cardiac output valves of more than 6.5 l/min in 6 of 7 patients. Cardiac output measurements across Hancock (SEE = 0.473 l/min) and St. Jude prostheses (SEE = 0.538 l/min) were more accurate than across Medtronic Hall prostheses (SEE = 0.847 l/min). Cardiac output can be calculated by pulsed Doppler echocardiography across normal functioning mitral prostheses. Due to the different flow dynamics the accuracy of cardiac output measurement depends on the prosthetic valve type. Reliable measurements of cardiac output can be performed across Hancock and St. Jude prostheses only. This method is limited in volume flow measurements across Medtronic Hall prostheses.
Authors:
H Dittmann; W Voelker; K R Karsch; L Seipel
Related Documents :
17574885 - Transthoracic echocardiography in estrela mountain dogs: reference values for the breed.
23041005 - Concentric left ventricular remodeling and aortic stiffness: a comparison of obesity an...
8055565 - Influence of intraballoon pressure on development of severe mitral regurgitation after ...
3711495 - Accuracy and pitfalls of doppler evaluation of the pressure gradient in aortic coarctat...
1996455 - Treatment of leptomeningeal carcinomatosis with continuous intraventricular infusion of...
22087995 - Effect of static pressure on acoustic energy radiated by cavitation bubbles in viscous ...
Publication Detail:
Type:  Comparative Study; Journal Article    
Journal Detail:
Title:  Klinische Wochenschrift     Volume:  68     ISSN:  0023-2173     ISO Abbreviation:  Klin. Wochenschr.     Publication Date:  1990 Mar 
Date Detail:
Created Date:  1990-05-18     Completed Date:  1990-05-18     Revised Date:  2006-11-15    
Medline Journal Info:
Nlm Unique ID:  2985205R     Medline TA:  Klin Wochenschr     Country:  GERMANY, WEST    
Other Details:
Languages:  eng     Pagination:  263-8     Citation Subset:  IM    
Affiliation:
Medizinische Klinik III, Eberhard-Karls-Universität Tübingen.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Adult
Aged
Bioprosthesis*
Blood Flow Velocity / physiology
Echocardiography, Doppler*
Exercise Test
Female
Heart Valve Prosthesis*
Humans
Male
Middle Aged
Mitral Valve / physiopathology,  surgery*
Postoperative Complications / diagnosis*,  physiopathology
Prosthesis Design

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Brain tumors in infants
Next Document:  Neurological outcome after a severe herpes simplex encephalitis treated with acyclovir and beta-inte...