Document Detail


Does a more "physiological" infant manikin design effect chest compression quality and create a potential for thoracic over-compression during simulated infant CPR?
MedLine Citation:
PMID:  23123431     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
Poor survivability following infant cardiac arrest has been attributed to poor quality chest compressions. Current infant CPR manikins, used to teach and revise chest compression technique, appear to limit maximum compression depths (CDmax) to 40mm. This study evaluates the effect of a more "physiological" CDmax on chest compression quality and assesses whether proposed injury risk thresholds are exceeded by thoracic over-compression. A commercially available infant CPR manikin was instrumented to record chest compressions and modified to enable compression depths of 40mm (original; CDmax(40)) and 56mm (the internal thoracic depth of a three-month-old male infant; CDmax(56)). Forty certified European Paediatric Life Support instructors performed two-thumb (TT) and two-finger (TF) chest compressions at both CDmax settings in a randomised crossover sequence. Chest compression performance was compared to recommended targets and compression depths were compared to a proposed thoracic over-compression threshold. Compressions achieved greater depths across both techniques using the CDmax(56), with 44% of TT and 34% of TF chest compressions achieving the recommended targets. Compressions achieved depths that exceeded the proposed intra-thoracic injury threshold. The modified manikin (CDmax(56)) improved duty cycle compliance; however, the chest compression rate was consistently too high. Overall, the quality of chest compressions remained poor in comparison with internationally recommended guidelines. This data indicates that the use of a modified manikin (CDmax(56)) as a training aid may encourage resuscitators to habitually perform deeper chest compressions, whilst avoiding thoracic over-compression and thereby improving current CPR quality. Future work will evaluate resuscitator performance within a more realistic, simulated CPR environment.
Authors:
Philip S Martin; Alison M Kemp; Peter S Theobald; Sabine A Maguire; Michael D Jones
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2012-10-31
Journal Detail:
Title:  Resuscitation     Volume:  -     ISSN:  1873-1570     ISO Abbreviation:  Resuscitation     Publication Date:  2012 Oct 
Date Detail:
Created Date:  2012-11-5     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  0332173     Medline TA:  Resuscitation     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Copyright Information:
Copyright © 2012. Published by Elsevier Ireland Ltd.
Affiliation:
Institute of Medical Engineering & Medical Physics, Cardiff School of Engineering, Cardiff University, CF24 3AA, Wales.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  High Density Lipoproteins Inhibit Vascular Endothelial Inflammation by Increasing 3?-Hydroxysteroid-...
Next Document:  Assessment of corneal endothelial cell density in patients with keratoconus not using contact lenses...