Distribution of target registration error for anisotropic and inhomogeneous fiducial localization error.
MedLine Citation:
PMID:  19423435     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
In point-based rigid-body registration, target registration error (TRE) is an important measure of the accuracy of the performed registration. The registration's accuracy depends on the fiducial localization error (FLE) which, in turn, is due to the measurement errors in the points (fiducials) used to perform the registration. FLE may have different characteristics and distributions at each point of the registering data sets, and along each orthogonal axis. Previously, the distribution of TRE was estimated based on the assumption that FLE has an independent, identical, and isotropic or anisotropic distribution for each point in the registering data sets. In this article, we present a general solution based on the Maximum Likelihood (ML) algorithm that estimates the distribution of TRE for the cases where FLE has an independent, identical or inhomogeneous, isotropic or anisotropic, distribution at each point in the registering data sets, and when an algorithm is available that is capable of calculating the optimum registration to first order. Mathematically, we show that the proposed algorithm simplifies to the one proposed by Fitzpatrick and West when FLE has an independent, identical, and isotropic distribution in the registering data sets. Furthermore, we use numerical simulations to show that the proposed algorithm accurately estimates the distribution of TRE when FLE has an independent, inhomogeneous, and anisotropic distribution in the registering data sets.
Authors:
Mehdi Hedjazi Moghari; Purang Abolmaesumi
Publication Detail:
Type:  Journal Article; Research Support, Non-U.S. Gov't     Date:  2009-05-05
Journal Detail:
Title:  IEEE transactions on medical imaging     Volume:  28     ISSN:  1558-254X     ISO Abbreviation:  IEEE Trans Med Imaging     Publication Date:  2009 Jun 
Date Detail:
Created Date:  2009-06-01     Completed Date:  2009-09-10     Revised Date:  2012-04-24    
Medline Journal Info:
Nlm Unique ID:  8310780     Medline TA:  IEEE Trans Med Imaging     Country:  United States    
Other Details:
Languages:  eng     Pagination:  799-813     Citation Subset:  IM    
Affiliation:
Department of Electrical and Computer Engineering, Queen's University, Kingston, ON, K7L 3N6 Canada.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Algorithms*
Anisotropy
Computer Simulation
Diagnostic Imaging
Humans
Image Processing, Computer-Assisted / methods*
Likelihood Functions
Monte Carlo Method
Normal Distribution
Surgical Procedures, Operative

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Intestinal motility assessment with video capsule endoscopy: automatic annotation of phasic intestin...
Next Document:  Permitted and forbidden sets in discrete-time linear threshold recurrent neural networks.