Document Detail


Direct and indirect quantification of mitral regurgitation with cardiovascular magnetic resonance, and the effect of heart rate variability.
MedLine Citation:
PMID:  20632070     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
OBJECT: Quantifying mitral regurgitation with cardiovascular magnetic resonance (CMR) involves indirect calculation, which increases the potential for error. We examined a direct quantification method using velocity mapping across the mitral valve, which may be less susceptible to error, and also examined the effect of heart rate variability on both techniques.
MATERIALS AND METHODS: Fifty-five patients underwent mitral regurgitation quantification with CMR by the direct method and two indirect methods-the standard method subtracting aortic flow (assessed by velocity mapping) from left ventricular stroke volume (assessed by cine imaging) and the 'volumetric' method using the difference between left and right ventricular stroke volumes. The methods were compared using Bland-Altman analyses.
RESULTS: Patients with low heart rate variability (beat-to-beat variability <30 bpm; n = 44) showed good agreement between direct and indirect methods (95% confidence limits for the difference between measurements +/-16.7 ml/11.8% regurgitant fraction for the standard method; +/-21.7 ml/15.4% for the volumetric method), with no significant offset (mean difference +2.8 ml/+1.9% for standard and +3.1 ml/+2.3% for volumetric methods). Patients with high heart rate variability (>30 bpm; n = 11) showed poor agreement between techniques (95% limits +/-80.3 ml/56.0%) and significant offset (mean difference +31.7 ml/+19.5%).
CONCLUSION: Direct quantification of mitral regurgitation with CMR compares well with indirect methods for patients with low heart rate variability, involves fewer calculations and is quick. All CMR measurements that use velocity mapping may be inaccurate, however, in patients with highly irregular rhythms and should be avoided in these patients.
Authors:
Saul G Myerson; Jane M Francis; Stefan Neubauer
Publication Detail:
Type:  Journal Article; Research Support, Non-U.S. Gov't     Date:  2010-07-15
Journal Detail:
Title:  Magma (New York, N.Y.)     Volume:  23     ISSN:  1352-8661     ISO Abbreviation:  MAGMA     Publication Date:  2010 Sep 
Date Detail:
Created Date:  2010-08-25     Completed Date:  2010-12-02     Revised Date:  2014-01-20    
Medline Journal Info:
Nlm Unique ID:  9310752     Medline TA:  MAGMA     Country:  Germany    
Other Details:
Languages:  eng     Pagination:  243-9     Citation Subset:  IM    
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Algorithms
Blood Flow Velocity / physiology
Cardiovascular System / physiopathology*
Heart Rate / physiology*
Humans
Magnetic Resonance Imaging*
Mitral Valve Insufficiency / diagnosis*,  physiopathology*
Reproducibility of Results
Grant Support
ID/Acronym/Agency:
//Department of Health

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Wavelet-encoding gradient-echo imaging sequence using real-time de-noising method for acquisition ti...
Next Document:  Pseudoprogression in patients with malignant gliomas treated with concurrent temozolomide and radiot...