Direct and indirect blood pressure measurements in baboons.
MedLine Citation:
PMID:  825507     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
The accuracy and precision of indirect blood pressure measurements in baboons were studied by comparing the results of indirect measurements with simultaneous direct measurements. The indirect measurements were made by four observers using a Doppler ultrasound instrument. A statistically significant difference between the two methods was found for systolic blood pressure but not for diastolic blood pressure. The indirect systolic averaged 13.8 mmHg higher than direct systolic and was found to be more precise than the indirect diastolic. The difference in blood pressure obtained by the two methods varied over animals and observers with an interaction between animals and observers. The effect of arm was examined by performing direct blood pressure measurements in both arms. No statistically significant arm effect was found.
Authors:
C A McMahan; H S Wigodsky; G T Moore
Related Documents :
24010017 - Vertical heterogeneity in predation pressure in a temperate forest canopy.
12375247 - Effect of total knee arthroplasty on blood flow to the lower limb: a prospective clinic...
486727 - Clinical suitability and accuracy of a new combined system for the transcutaneous and i...
20139327 - Chronic ankle instability alters central organization of movement.
21478747 - Lung impedance measurements to monitor alveolar ventilation.
2316017 - Intraoperative evaluation of eurocollins and university of wisconsin preservation solut...
Publication Detail:
Type:  Journal Article; Research Support, U.S. Gov't, P.H.S.    
Journal Detail:
Title:  Journal of applied physiology     Volume:  41     ISSN:  0021-8987     ISO Abbreviation:  J Appl Physiol     Publication Date:  1976 Nov 
Date Detail:
Created Date:  1977-01-25     Completed Date:  1977-01-25     Revised Date:  2006-11-15    
Medline Journal Info:
Nlm Unique ID:  0376576     Medline TA:  J Appl Physiol     Country:  UNITED STATES    
Other Details:
Languages:  eng     Pagination:  806-9     Citation Subset:  IM    
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Animals
Blood Pressure Determination / methods*
Female
Haplorhini
Papio

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Design for a micropowered multichannel PAM/FM biotelemetry system for brain research.
Next Document:  Analysis and optimization of a quantitative organic soil neutralization test for disinfectants.