Document Detail


Differential counting of blood leukocytes using automated microscopy and a decision support system based on artificial neural networks--evaluation of DiffMaster Octavia.
MedLine Citation:
PMID:  12755789     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
The morphological appearance of blood cells has an established association to clinical conditions. A novel system, DiffMaster Octavia for differential counting of blood leukocytes, has been evaluated. The system consisted of a microscope, 3-chip color charge coupled device (CCD) camera, automated motorized stage holder, electronic hardware for motor and light control and software for automatic cell location and image processing for preclassification of blood cells using artificial neural networks. The DiffMaster test method, was evaluated on 322 routine blood samples (400 cells per sample) using manual microscopy as reference method. The results showed a correlation of determination (r(2)) of 0.8-0.98 for the normal cell classes and blast cells. The DiffMaster correctly preclassified 89% of all leukocytes with a good reproducibility. After verification of the cell classes, the agreement between the test and reference method was 91% whether the sample was abnormal or normal. The clinical sensitivity was 98% and specificity 82%. The sensitivity to identify blast cells was slightly higher with the DiffMaster than manual microscopy. Similar levels of short-term imprecision for the two methods were found for all cell classes. In conclusion this study shows that the DiffMaster can provide a decision support system which, together with a qualified morphologist, can generate leukocyte differential count reports of high quality.
Authors:
B Swolin; P Simonsson; S Backman; I Löfqvist; I Bredin; M Johnsson
Related Documents :
11333329 - Identifying the origin of single corneal cells by dna fingerprinting: part i--implicati...
18537989 - Further analysis of assessments of the coefficient of variation of corneal endothelial ...
7258859 - Cybest-cdms; automated cell dispersion and monolayer smearing device for cybest.
1507189 - Fetal cells in the maternal circulation.
15679339 - Separation of sperm and epithelial cells in a microfabricated device: potential applica...
8152899 - Performance evaluation of the haematological analyser cell-dyn 3000 (abbott).
15749669 - Stem cell plasticity: time for a reappraisal?
18429039 - In vitro labeling of glioma cells with gadofluorine m enhances t1 visibility without af...
22107969 - Utf1 deficiency promotes retinoic acid-induced neuronal differentiation in p19 embryona...
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Clinical and laboratory haematology     Volume:  25     ISSN:  0141-9854     ISO Abbreviation:  Clin Lab Haematol     Publication Date:  2003 Jun 
Date Detail:
Created Date:  2003-05-20     Completed Date:  2004-04-13     Revised Date:  2004-11-17    
Medline Journal Info:
Nlm Unique ID:  7907061     Medline TA:  Clin Lab Haematol     Country:  England    
Other Details:
Languages:  eng     Pagination:  139-47     Citation Subset:  IM    
Affiliation:
Department of Clinical Chemistry and Transfusion Medicine, Sahlgrenska University Hospital, Göteborg University, Sweden. birgitta.swolin@clinchem.gu.se
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Automation
Blast Crisis / diagnosis,  pathology
Blood Cell Count / instrumentation
Humans
Image Processing, Computer-Assisted*
Leukocyte Count / instrumentation*
Microscopy / instrumentation*
Neural Networks (Computer)*
Reproducibility of Results
Sensitivity and Specificity

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Ten-year follow-up in a maxillary sinus augmentation using anorganic bovine bone (Bio-Oss). A case r...
Next Document:  Adding a caveat to the urgent clinical notification of anaemia does not reduce inappropriate emergen...