Document Detail


Diagnostic accuracy of mammography readers and their memory performance have no correlation with each other.
MedLine Citation:
PMID:  20718911     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
INTRODUCTION: The study aims to determine if any association exists between visual memory performance and diagnostic accuracy performance in a group of radiologist mammogram readers.
MATERIALS AND METHODS: One hundred proven mammograms (23 with cancers) were grouped into 5 sets of 20 cases, with sets being of equal difficulty. Pairs of sets were presented in 5 reads (40 cases per read, order random) to a panel of 8 radiologist readers (either present or past screening readers, with experience range from <1 year to >20 years). The readers were asked to either 'clear' or 'call back' cases depending on need for further workup, and at post-baseline reads to indicate whether each case was 'new' or 'old' (i.e. remembered from prior read). Two sets were presented only at baseline (40 cases per reader), and were used to calculate the reader's false recollection rate. Three sets were repeated post-baseline once or twice (100 cases per reader). Reading conditions were standardised.
RESULTS: Memory performance differed markedly between readers. The number of correctly remembered cases (of 100 'old' cases) had a median of 10.5 and range of 0-58. The observed number of false recollections (of 40 'totally new' cases) had a median of 2 and range of 0-17. Diagnostic performance measures were mean (range): sensitivity 0.68 (0.54-0.81); specificity 0.82 (0.74-0.91); positive predictive value (PPV) 0.55 (0.50-0.65); negative predictive value (NPV) 0.89 (0.86-0.93) and accuracy 0.78 (0.76-0.83). Confidence intervals (CIs; 95%) for each reader overlapped for all the diagnostic parameters, indicating a lack of statistically significant difference between the readers at the 5% level. The most sensitive and the most specific reader showed a trend away from each other on sensitivity, specificity, NPV and PPV; their accuracies were 0.76 and 0.82, respectively, and their accuracy 95% CIs overlapped considerably. Correlation analysis by reader showed no association between observed memory performance and any of the diagnostic accuracy measures in our group of readers. In particular, there was no correlation between diagnostic accuracy and memory performance.
CONCLUSION: There was no association between visual memory performance and diagnostic accuracy as a screening mammographer in our group of eight representative readers. Whether a radiologist has a good or a bad visual memory for cases, and in particular mammograms, should not impact on his or her performance as a radiologist and mammogram reader.
Authors:
P Kok; A G Pitman; J N Cawson; S Gledhill; S Kremer; J Lawson; K Mehta; V Mercuri; D Shnier; R Taft; L Zentner
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Journal of medical imaging and radiation oncology     Volume:  54     ISSN:  1754-9485     ISO Abbreviation:  J Med Imaging Radiat Oncol     Publication Date:  2010 Aug 
Date Detail:
Created Date:  2010-08-19     Completed Date:  2010-12-14     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  101469340     Medline TA:  J Med Imaging Radiat Oncol     Country:  Australia    
Other Details:
Languages:  eng     Pagination:  315-24     Citation Subset:  IM    
Affiliation:
University of Melbourne, Melbourne, Victoria, Australia. phebekok@yahoo.com
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Breast Neoplasms / diagnosis*
Clinical Competence / statistics & numerical data*
Diagnostic Errors / statistics & numerical data
Female
Humans
Mammography / methods*,  statistics & numerical data*
Memory*
Mental Recall
Observer Variation
Predictive Value of Tests
Reproducibility of Results
Sensitivity and Specificity
Task Performance and Analysis

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Long-term outcomes of vertebroplasty for osteoporotic compression fractures.
Next Document:  Pilot comparison of F-fluorocholine and F-fluorodeoxyglucose PET/CT with conventional imaging in pro...