Diagnostic accuracy of the conventional 12-lead and the orthogonal Frank-lead electrocardiograms in detection of myocardial infarctions with classifiers using continuous and Bernoulli features.
MedLine Citation:
PMID:  7365357     Owner:  NLM     Status:  MEDLINE    
The performance of ECG classifiers using Bernoulli variables was evaluated in comparison with the same classifiers using an identical set of ECG features measured in continuum. A Bernoulli variable is permitted to take only two states depending on whether its value is below or above a given threshold. A new method was used for discretization threshold optimization. The branch-and-bound algorithm, the sequential forward selection and backward rejection procedures were used for selecting the best subsets of Bernoulli and continuous features out of the primary set of features measured from the conventional 12-lead and the orthogonal Frank-lead ECG. A linear discriminant function was used to estimate the classification accuracy of Bernoulli and continuous features in a test library composed of ECGs of 237 Subjects with old myocardial infarcts and 299 subjects without infarction. The results indicate that while Bernoulli variables perform as well as or better than continuous variables over a wide range of sensitivity and specificity, continuous features appear to yield a higher diagnostic accuracy when a high level of specificity is required. In comparison with the diagnostic accuracy of the Minnesota Code's criteria for myocardial infarction, decision-theoretic classifiers using continuous features yielded an overall improvement in sensitivity from 14 to 20% at a fixed level of specificity. The information content of the conventional 12-lead ECG appeared as good as or better than that of the orthogonal Frank-lead ECG regarding differential diagnosis between myocardial infarction and non-infarction groups when identical statistical procedures were used for the design of the classifiers.
U Jain; P M Rautaharju
Related Documents :
15273457 - T wave oversensing in implantable cardioverter defibrillators.
933327 - A clinical study on familial heart diseases.
19808427 - Ecg quantification of myocardial scar in cardiomyopathy patients with or without conduc...
15842427 - Magnetocardiogram recordings in a nonshielded environment--reproducibility and ischemia...
18653707 - Transforming growth factor-beta blockade down-regulates the renin-angiotensin system an...
2464547 - Left ventricular size and function in double inlet left ventricle.
Publication Detail:
Type:  Comparative Study; Journal Article    
Journal Detail:
Title:  Journal of electrocardiology     Volume:  13     ISSN:  0022-0736     ISO Abbreviation:  J Electrocardiol     Publication Date:  1980 Apr 
Date Detail:
Created Date:  1980-06-25     Completed Date:  1980-06-25     Revised Date:  2009-11-11    
Medline Journal Info:
Nlm Unique ID:  0153605     Medline TA:  J Electrocardiol     Country:  UNITED STATES    
Other Details:
Languages:  eng     Pagination:  159-66     Citation Subset:  IM    
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Electrocardiography / classification*,  methods
Myocardial Infarction / diagnosis*
Statistics as Topic

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine

Previous Document:  Ventricular tachyarrhythmias in regional myocardial hyperkalemia: efficacy of three antiarrhythmic a...
Next Document:  Value of premature ventricular contraction morphology in the detection of myocardial infarction.