Diagnostic Performance of Dark-Blood T2-Weighted CMR for Evaluation of Acute Myocardial Injury.
MedLine Citation:
PMID:  23192160     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
OBJECTIVES: We compared the image quality and diagnostic performance of 2 fat-suppression methods for black-blood T2-weighted fast spin-echo (FSE), which are as follows: (a) short T1 inversion recovery (STIR; FSE-STIR) and (b) spectral adiabatic inversion recovery (SPAIR; FSE-SPAIR), for detection of acute myocardial injury. BACKGROUND: Edema-sensitive T2-weighted FSE cardiac magnetic resonance (CMR) imaging is useful in detecting acute myocardial injury but may experience reduced myocardial signal and signal dropout. The SPAIR pulse aims to eliminate artifacts associated with the STIR pulse. MATERIALS AND METHODS: A total of 65 consecutive patients referred for CMR evaluation of myocardial structure and function underwent FSE-STIR and FSE-SPAIR, in addition to cine and late gadolinium enhancement (LGE) CMR. T2-weighted FSE images were independently evaluated by 2 readers for image quality and artifacts (Likert scale of 1-5; best-worst) and presence of increased myocardial signal suggestive of edema. In addition, clinical CMR interpretation, incorporating all CMR sequences available, was recorded for comparison. Diagnostic performance of each T2-weighted sequence was measured using recent (<30 days) troponin elevation greater than 2 times the upper limit of normal as the reference standard for acute myocardial injury. RESULTS: Of the 65 patients, there were 21 (32%) with acute myocardial injury. Image quality and artifact scores were significantly better with FSE-SPAIR compared with FSE-STIR (2.15 vs 2.68, P < 0.01; 2.62 vs 3.05, P < 0.01, respectively). The sensitivity, specificity, positive predictive value, and negative predictive value for acute myocardial injury were as follows: 29%, 93%, 67%, and 73% for FSE-SPAIR; 38%, 91%, 67%, and 75% for FSE-STIR; 71%, 98%, 94%, and 88% for clinical interpretation including LGE, T2, and wall motion. There was a statistically significant difference in sensitivity between the clinical interpretation and each of the T2-weighted sequences but not between each T2-weighted sequence. CONCLUSIONS: Although FSE-SPAIR demonstrated significantly improved image quality and decreased artifacts, isolated interpretations of each T2-weighted technique demonstrated high specificity but overall low sensitivity for the detection of myocardial injury, with no difference in accuracy between the techniques. However, real-world interpretation in combination with cine and LGE CMR methods significantly improves the overall sensitivity and diagnostic performance.
Authors:
Monvadi B Srichai; Ruth P Lim; Narayan Lath; James Babb; Leon Axel; Daniel Kim
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2012-11-27
Journal Detail:
Title:  Investigative radiology     Volume:  -     ISSN:  1536-0210     ISO Abbreviation:  Invest Radiol     Publication Date:  2012 Nov 
Date Detail:
Created Date:  2012-11-29     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  0045377     Medline TA:  Invest Radiol     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Affiliation:
From the *Department of Radiology, New York University School of Medicine, New York, NY; †Department of Radiology, Singapore General Hospital, Singapore, Singapore; and ‡Department of Radiology, University of Utah, Salt Lake City, UT.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Toward functional nanocomposites: taking the best of nanoparticles, polymers, and small molecules.
Next Document:  Use of Intravoxel Incoherent Motion MR Imaging to Assess Placental Perfusion in a Murine Model of Pl...