Abstract/OtherAbstract:
BACKGROUND: No previous studies have validated the use of portable monitoring (PM) for the diagnosis of obstructive sleep apnea (OSA) in morbidly obese individuals. Our aim was to investigate the accuracy of PM for detecting respiratory events in morbidly obese patients that will be undergoing bariatric surgery.
METHODS: This was a prospective study involving patients with body mass index (BMI) ≥35 kg/m(2) who were recruited from the Sleep Clinic of Universidade Federal de São Paulo. Sleep-disordered breathing (SDB) was evaluated during full-night polysomnography (PSG). PM use was randomized and used on two consecutive nights: (1) at home (STDHome) and (2) at the sleep laboratory with PSG (PSG_STDLab).
RESULTS: Although 58 participants initially underwent the recordings, 26 (45 %) were excluded because of technical problems. The patients' mean age was 42.9 ± 10.9 (SD) years, and 56 % were female. The mean BMI was 40.8 ± 5.2 kg/m(2). All patients had high risk for OSA, as defined by the Stop-Bang questionnaire, and the mean apnea-hypopnea index (AHI) was 46.9 ± 30.4/h. The intraclass coefficient of the correlation between AHI_PSG and AHI_STDLab was r = 0.92 (p = 0.0001); the intraclass coefficient for AHI_PSG and AHI_STDHome was r = 0.84 (p = 0.0001). The Kappa index was 0.87 (p > 0.0001) for severe cases. The sensitivity and the positive predictive value increased with the disease severity. A Bland-Altman analysis showed good agreement between the investigated methods.
CONCLUSIONS: PM is an efficacious method for diagnosing OSA in obese patients who have a high clinical probability of the disease. The method displays good sensitivity and specificity in severe cases; nevertheless, the high rate of data loss must be taken into account.
Authors:
Márcia G Oliveira; Erika C Treptow; Cesar Fukuda; Luiz E Nery; Rosana M Valadares; Sérgio Tufik; Lia Bittencourt; Sonia M Togeiro
Related Documents :
16857506 - Effect of the morcher capsular tension ring on refractive outcome.
10507576 - Combined temporal phacoemulsification and pars plana vitrectomy for the treatment of ca...
25260056 - Sleep apnea in patients with chronic kidney disease: a single center experience.
8675396 - The role of prostaglandins e2 and f2 alpha in ultraviolet radiation-induced cortical ca...
8160386 - Pointing errors in strabismics: complex patterns of distorted visuomotor coordination.
17725616 - Endogenous endophthalmitis: microorganisms, disposition and prognosis.
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2014-10-25
Journal Detail:
Title:  Obesity surgery     Volume:  -     ISSN:  1708-0428     ISO Abbreviation:  Obes Surg     Publication Date:  2014 Oct 
Date Detail:
Created Date:  2014-10-25     Completed Date:  -     Revised Date:  2014-10-26    
Medline Journal Info:
Nlm Unique ID:  9106714     Medline TA:  Obes Surg     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  How Physician Obesity Medicine Specialists Treated Obesity before 2012 New Drug Approvals.
Next Document:  Retro-renal colon: role in percutaneous access.