Document Detail


Device closure of atrial septal defects with the Amplatzer septal occluder: safety and outcome in infants.
MedLine Citation:
PMID:  17903514     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
OBJECTIVE: Device closure of secundum atrial septal defects is sometimes needed in young children; however, little is known about the safety and outcome of this procedure in infants. In this study, the safety and efficacy of secundum atrial septal defect closure with the Amplatzer septal occluder (AGA Medical Corp, Golden Valley, Minn) was evaluated in patients less than 1 year of age. METHODS: Between July 1999 and September 2006, atrial septal defect closure with the Amplatzer septal occluder was attempted in 15 infants at our institution. The patients ranged in age from 0.5 to 11.9 months (mean +/- standard deviation; 8.2 +/- 3.7 months) in the percutaneous group and from 2.2 to 3.4 months (2.9 +/- 0.6 months) in the peratrial group. Their weights ranged from 3.8 to 8.3 kg (5.5 +/- 1.7 kg) and from 3.0 to 4.0 kg (3.4 +/- 0.6 kg) in each group, respectively. The indications for atrial septal defect closure were failure to thrive, significant chamber enlargement, hemodynamically significant shunts, and prehepatic transplantation. The size of the defect as measured by intracardiac echocardiography (n = 3) or transesophageal echocardiography (n = 12) ranged from 2.0 to 16 mm (8.0 +/- 4.4 mm). RESULTS: The pulmonary/systemic flow ratio ranged from 1.0 to 9.0 (2.8 +/- 2.0). The device was successfully placed in 14 of 15 infants. The size of the Amplatzer septal occluder device implanted ranged from 4 to 20 mm (10.1 +/- 4.3 mm). It was percutaneously deployed in 11 of 14 patients and by the hybrid or peratrial approach (open chest off-pump) in 3 of 14 infants. In infants who had a successful attempt (n = 14), the complete closure rates at 24 hours and 1 year were 86% and 100%, respectively. In 3 of 15 infants, minor complications occurred: transient arrhythmias (n = 2) and blood transfusion (n = 1). One patient had a major complication (vascular intimal injury with thrombosis of the inferior vena cava). One patient with Down syndrome died 6 weeks later of progressive pulmonary hypertension. The follow-up time ranged from 0.6 to 6.9 years (3.2 +/- 1.9 years). At follow-up, clinical development and growth improved in all children with failure to thrive, and all ventilator-dependent children could be weaned shortly after closure of the atrial septal defect. CONCLUSION: Device closure of atrial septal defects is an effective and fairly safe alternative to surgery in infants. Hybrid or peratrial closure is also an alternative to percutaneous closure in the very small infant.
Authors:
Karim A Diab; Qi-Ling Cao; Emile A Bacha; Ziyad M Hijazi
Related Documents :
80224 - Maternal plasma alpha-fetoprotein screening for fetal neural tube defects.
7533534 - Expression of cellular fibronectin and tenascin in the rabbit cornea after excimer lase...
7377154 - Transient 'lazy-leukocyte' syndrome during infancy.
7002204 - A clinical trial on the early detection and correction of haemostatic defects in select...
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  The Journal of thoracic and cardiovascular surgery     Volume:  134     ISSN:  1097-685X     ISO Abbreviation:  J. Thorac. Cardiovasc. Surg.     Publication Date:  2007 Oct 
Date Detail:
Created Date:  2007-10-01     Completed Date:  2007-11-08     Revised Date:  2009-11-03    
Medline Journal Info:
Nlm Unique ID:  0376343     Medline TA:  J Thorac Cardiovasc Surg     Country:  United States    
Other Details:
Languages:  eng     Pagination:  960-6     Citation Subset:  AIM; IM    
Affiliation:
Department of Pediatrics, University of Chicago Comer Children's Hospital, Pritzker School of Medicine, Chicago, Ill, USA.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Echocardiography, Transesophageal
Electrocardiography
Female
Fluoroscopy
Follow-Up Studies
Heart Catheterization
Heart Septal Defects, Atrial / radiography,  surgery*,  ultrasonography
Humans
Infant
Infant, Newborn
Male
Prosthesis Implantation / instrumentation*
Radiography, Interventional
Severity of Illness Index
Time Factors
Treatment Outcome
Ultrasonography, Interventional