Device capable of reducing gastric inflation during artificial ventilation in a manikin model.
MedLine Citation:
PMID:  18486408     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Gastric inflation is a significant issue when ventilation is performed in cases of unprotected airway. The objective of this study was to compare the amounts of gastric insufflation and tidal volumes produced by a hose-extended bag-valve-mask (BVM) device supplemented by an interposed reservoir bag with a similar BVM without the reservoir in a simulated human model. Fourteen academic dental staff members performed 10 ventilations on a manikin using the reservoir-supplemented device in comparison to the control BVM in a randomized order. Lung compliance was adjusted to 45 (high) and 4.5 mL/mbar (low), and the lower esophageal sphincter pressure (LOSP) simulator to a pressure of 15 and 3 mbar, respectively, in different settings. Lower tidal volumes were observed with the new device than with the control BVM at high compliance with LOSP of 15 mbar (median 506 vs. 787 mL, respectively; p = 0.0002) and LOSP of 3 mbar (median 544 vs. 794 mL, respectively; p = 0.0006), as well as during ventilation at low lung compliance and LOSP of 3mbar (median 131 vs. 163 mL, respectively; p = 0.0342). No differences were detected at low lung compliance and LOSP of 15 mbar (median 175 vs. 194 mL; p = 0.3804). Gastric inflation almost exclusively occurred in case of low lung compliance, being markedly lower with the new device than with the control device at 15 mbar LOSP (300 vs. 2225 mL, respectively; p = 0.0006), and at 3 mbar LOSP (1138 vs. 3050 mL, respectively; p = 0.0001). Application of the hose-extended bag-valve-mask device supplemented with a reservoir bag reduces tidal volumes. Marked reduction of gastric inflation by use of this device becomes effective under conditions with low lung compliance.
Authors:
Till Mutzbauer; Georg Tabacek
Related Documents :
18496298 - A self-measurement device suitable for hospital use: validation of the spengler pro m a...
6536278 - Inflatable splints--what are they doing?
16876678 - Accuracy of ambulatory blood pressure monitors in routine clinical practice.
20113128 - A new streaming potential chamber for zeta potential measurements of particulates.
8194798 - Body-plethysmographic pressure-flow diagrams in chronic obstructive lung disease. i. co...
2441888 - Resuscitation in haemorrhagic shock--pulmonary and renal effects: an adverse effect of ...
Publication Detail:
Type:  Journal Article     Date:  2008-05-16
Journal Detail:
Title:  The Journal of emergency medicine     Volume:  38     ISSN:  0736-4679     ISO Abbreviation:  J Emerg Med     Publication Date:  2010 May 
Date Detail:
Created Date:  2010-05-10     Completed Date:  2010-09-13     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  8412174     Medline TA:  J Emerg Med     Country:  United States    
Other Details:
Languages:  eng     Pagination:  428-33     Citation Subset:  IM    
Copyright Information:
Copyright (c) 2010 Elsevier Inc. All rights reserved.
Affiliation:
Department of Craniomaxillofacial Surgery, University of Zurich Dental Center, Zurich, Switzerland.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Equipment Design*
Humans
Lung Compliance
Manikins*
Masks*
Respiration, Artificial / instrumentation*
Tidal Volume

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Focusing on a "serious" review of systems in the emergency department.
Next Document:  Emergency department presentation of a rare neurological disorder.