Document Detail


Development and validation of a new automatic algorithm for quantification of left ventricular volumes and function in gated myocardial perfusion SPECT using cardiac magnetic resonance as reference standard.
MedLine Citation:
PMID:  21761374     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
BACKGROUND: By gating image acquisition in myocardial perfusion SPECT (MPS) to ECG, left ventricular (LV) volumes and function can be determined. Several previous studies have shown that existing MPS software packages underestimate LV volumes compared to cardiac magnetic resonance (CMR). The aim of this study was therefore to develop a new LV segmentation algorithm for gated MPS using CMR as reference standard. METHODS AND RESULTS: A total of 126 patients with suspected coronary artery disease, who underwent both gated MPS and CMR were retrospectively included. The proposed LV segmentation algorithm (Segment) was trained in 26 patients, and tested in 100 patients in comparison to four commercially available MPS software packages (QGS, MyoMetrix, ECTb, and Exini) using CMR as reference standard. Mean bias ± SD between MPS and CMR was for EDV -5% ± 12%, -43% ± 8%, -40% ± 8%, -42% ± 9%, -32% ± 7%, for ESV 0% ± 17%, -41% ± 16%, -34% ± 15%, -54% ± 13%, -41% ± 10%, for EF -2% ± 13%, -1% ± 14%, -7% ± 15%, 17% ± 16%, 10% ± 17% for Segment, QGS, MyoMetrix, ECTb, and Exini, respectively, and for LVM 3% ± 18%, 33% ± 25%, 37% ± 24% for Segment, QGS, and ECTb, respectively. Correlation between MPS by Segment and CMR were for EDV R (2) = 0.89, for ESV R (2) = 0.92, for EF R (2) = 0.69, and for LVM R (2) = 0.72, with no difference compared to the correlation between the other MPS software packages and CMR (EDV R (2) = 0.86-0.92, ESV R (2) = 0.91-0.93, EF R (2) = 0.64-0.65, and LVM R (2) = 0.68-0.70). CONCLUSION: The Segment software quantifies LV volumes and EF by MPS with similar correlation and a low bias compared to other MPS software packages, using CMR as reference standard. Hence, the Segment software shows potential to provide clinically relevant volumes and functional values from MPS.
Authors:
Helen Soneson; Fredrik Hedeer; Carmen Arévalo; Marcus Carlsson; Henrik Engblom; Joey F A Ubachs; Håkan Arheden; Einar Heiberg
Related Documents :
1735064 - Lower extremity arterial occlusive disease.
9395164 - Comparison of the effects of regional ischemia and hyperkalemia on the membrane action ...
3630934 - Effects of titrated beta blockade (metoprolol) on silent myocardial ischemia in ambulat...
1666054 - Prolonged period of global ischemia causes no change in the gtp-binding proteins in the...
6441734 - Treatment of unstable angina with emphasis on calcium antagonists.
12667244 - An unusual native tricuspid valve endocarditis caused by candida colliculosa.
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2011-7-15
Journal Detail:
Title:  Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology     Volume:  -     ISSN:  1532-6551     ISO Abbreviation:  -     Publication Date:  2011 Jul 
Date Detail:
Created Date:  2011-7-15     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  9423534     Medline TA:  J Nucl Cardiol     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Affiliation:
Department of Clinical Physiology, Skåne University Hospital, Lund University, SE-22185, Lund, Sweden.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Configural representations in spatial working memory: modulation by perceptual segregation and volun...
Next Document:  Stress-only or stress/rest myocardial perfusion imaging in patients undergoing evaluation for bariat...