Document Detail

Development and validation of a HPLC-MS/MS method with electrospray ionization for quantitation of potassium oxonate in human plasma: Application to a pharmacokinetic study.
Jump to Full Text
MedLine Citation:
PMID:  23407381     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
A rapid, sensitive and specific HPLC-MS/MS method was developed and validated for the quantification of potassium oxonate (Oxo) in human plasma using [(13)C(2),(15)N(3)]-Oxo as an internal standard (IS). The target substance was separated from human plasma using the solid-phase extraction method. Chromatography separation was performed on a Waters:Atlantis dC(18) column (150×4.6 mm, 5.0 μm) with a mobile phase consisting of H(2)O with 0.1% formic acid in acetonitrile (90:10, v/v). The mass spectrometer works with electrospray ionization and multiple reaction monitoring in its negative ion mode, using target ions at [M-H](-) m/z 111.9 for Oxo and [M-H](-) m/z 117.0 for the IS. The mean standard curve was linear (r=0.9991) over the concentration range of 2.0-200.0 ng/ml and had good back-calculated accuracy and precision. The intra- and inter-day precision were <6.33% and the accuracy was >99.38%. The extraction recovery was >60.26%. The lower limit of quantification achieved with this method was 2.0 ng/ml. This assay method was demonstrated to be accurate, sensitive and simple and was successfully applied to a pharmacokinetic study following single oral administration of a 40-mg S-1 capsule in 12 tumor patients.
Authors:
Guangtao Hao; Shaobo Bai; Haixia Liang; Yuguang Liang; Hengyan Qu; Hongzhi Gao; Yuanyuan Li; Zhuanjie Zheng; Xiaofang Wang; Zeyuan Liu
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2013-1-18
Journal Detail:
Title:  Experimental and therapeutic medicine     Volume:  5     ISSN:  1792-0981     ISO Abbreviation:  Exp Ther Med     Publication Date:  2013 Mar 
Date Detail:
Created Date:  2013-2-14     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  101531947     Medline TA:  Exp Ther Med     Country:  -    
Other Details:
Languages:  ENG     Pagination:  932-936     Citation Subset:  -    
Affiliation:
Department of Pharmacology, Affiliated Hospital of the Academy of Military Medical Sciences, Beijing 100071;
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine

Full Text
Journal Information
Journal ID (nlm-ta): Exp Ther Med
Journal ID (iso-abbrev): Exp Ther Med
Journal ID (publisher-id): ETM
ISSN: 1792-0981
ISSN: 1792-1015
Publisher: D.A. Spandidos
Article Information
Download PDF
Copyright © 2013, Spandidos Publications
open-access:
Received Day: 12 Month: 11 Year: 2012
Accepted Day: 28 Month: 12 Year: 2012
Print publication date: Month: 3 Year: 2013
Electronic publication date: Day: 18 Month: 1 Year: 2013
pmc-release publication date: Day: 18 Month: 1 Year: 2013
Volume: 5 Issue: 3
First Page: 932 Last Page: 936
PubMed Id: 23407381
ID: 3570248
DOI: 10.3892/etm.2013.908
Publisher Id: etm-05-03-0932

Development and validation of a HPLC-MS/MS method with electrospray ionization for quantitation of potassium oxonate in human plasma: Application to a pharmacokinetic study
GUANGTAO HAO1*
SHAOBO BAI2*
HAIXIA LIANG3
YUGUANG LIANG1
HENGYAN QU1
HONGZHI GAO1
YUANYUAN LI1
ZHUANJIE ZHENG1
XIAOFANG WANG1
ZEYUAN LIU1
1Department of Pharmacology, Affiliated Hospital of the Academy of Military Medical Sciences, Beijing 100071;
2Pharmacy Department, The Fifth Hospital of PLA, Yinchuan 750004;
3Department of Pharmacy, Beijing Anding Hospital, Capital Medical University, Beijing 100088, P.R. China
Correspondence: Correspondence to: Dr Zeyuan Liu, Department of Pharmacology, Affiliated Hospital of the Academy of Military Medical Sciences, No.8. East Street, Fengtai, Beijing 100071, P.R. China, E-mail: yls307@126.com
*Contributed equally

Introduction

S-1 is widely administered to gastric cancer patients and consists of tegafur (FT), gimeracil (CDHP) and potassium oxonate (Oxo; 1,2,3,4-etetrahydro-2,4-dioxo-1,3,5-triazin-6-carboxylate) in a molar ratio of 1:0.4:1 (17). FT is converted to 5-fluorouracil (5-FU), which has an anticancer role in vivo. However, 5-FU has some disadvantages, including a short half-life in vivo, which causes gastrointestinal tract and bone marrow toxicity. CDHP and Oxo act as modulators, which have no anticancer activity when used singly. CDHP competitively inhibits dihydropyrimidine dehydrogenase to maintain a high plasma concentration of 5-FU (8). Oxo relieves the gastrointestinal tract toxicity induced by 5-FU (9). CDHP and Oxo facilitate the function of 5-FU, which leads to improved therapeutic effects (10). Oxo is converted into oxonic acid (Fig. 1) in vivo.

To date, there are several methods reported in the literature to determine Oxo, including enzyme immunoassay (11), GC-NICI-MS (gas chromatography-negative ion chemical ionization mass spectrometry) (12,13) and LC-MS/MS (liquid chromatography-tandem mass spectrometry) (1417). The enzyme immunoassay method is not suitable for analysis in large batches. The GC-NICI-MS method has been shown to be unstable when used clinically. The LC-MS/MS method is reported to require long and complex pre-processing for derivatization. Therefore, a simple and novel method is required. In this study, a novel HPLC-MS/MS method was developed and successfully applied to a pharmacokinetic study, after single oral administration of a combination of FT, CDHP and Oxo to 12 tumor patients. This method was determined to be simple, rapid and stable for use in the quantitation of Oxo in human plasma.


Materials and methods
Chemicals and reagents

Potassium oxonate (purity, 99.60%) was supplied by the National Institute for the Control of Pharmaceutical and Biological Products (Beijing, China). [13C2,15N3]-Oxo (purity, 99.8%) was purchased from Toronto Research Chemicals Inc. (Toronto, ON, Canada). Methanol, acetonitrile and formic acid (LC grade) were purchased from Dima Technology Inc. (Richmond Hill, ON, Canada). The other chemicals (analytical grade) were supplied by Beijing Chemical Co. (Beijing, China). Deionized H2O was prepared using a Milli-Q H2O purifying system, purchased from Millipore Corporation (Bedford, MA, USA). Blank (drug-free) human plasma was obtained from healthy subjects.

Preparation of stock and working solutions

The stock solutions were prepared separately in methanol-H2O [1:1, v/v; 400.0 μg/ml for Oxo and 40.0 μg/ml for the internal standard (IS)]. Routine daily calibration curves were prepared in drug-free plasma. Appropriate volumes of stock solutions and drug-free human plasma were added to each test tube to prepare working solutions at concentrations of 2.0, 5.0, 10.0, 25.0, 50.0, 100.0 and 200.0 ng/ml. Contemporary quality control samples, which were run in each assay, were also prepared at concentrations of 5.0, 25.0 and 160.0 ng/ml. Working solutions of IS (250.0 ng/ml) were obtained by diluting the stock solution with methano-H2O (1:1, v/v). The standard solutions and IS were stored at −20°C.

HPLC-MS/MS analysis

HPLC was performed on a Shimadzu HPLC system consisting of a LC-20AD binary pump, a DGU-20A3 degasser, a SIL-20A autosampler and a CTO-10ASVP column oven (Shimadzu Corporation, Kyoto, Japan). Chromatographic separation was achieved on a Waters:Atlantis dC18 column (150x4.6 mm, 5.0 μm, Waters, Milford, MA, USA) maintained at 20°C in the column oven. The signal acquisition and peak integration were performed by Analyst 1.4.2 software (Applied Biosystems, Foster City, CA, USA). The mobile phase was H2O containing 0.1% formic acid-acetonitrile (90:10, v/v), with a flow rate of 1.2 ml/min (70% shunting). Detection was carried out on an API 3200 MS/MS System (Applied Biosystems) equipped with an electrospray ionization (ESI) source in the negative ionization mode. Multiple reaction monitoring (MRM) at unit resolution was employed to monitor the transitions of Oxo at m/z 156.0→111.9 and IS at m/z 161.1→117.1. The operating parameters of ESI-mass spectrometry (ESI-MS) were as follows: curtain gas, 15 psi; gas 1, 40 psi; gas 2 (nitrogen), 80 psi; dwell time, 150 msec; ion spray voltage, −4.5 kV; ion source temperature, 550°C; declustering potential (DP), −20 V; collision energy (CE), −11 V.

Sample preparation

Briefly, 50 μl IS working solution and 200 μl deionized H2O were added to a 50-μl aliquot of human plasma in a 1.5-ml Eppendorf tube. The mixture was vortex-mixed for 30 sec at 20°C. The SPE column was activated by the elution of 350 μl methanol and 350 μl H2O. Plasma samples were loaded to the SPE column and the column was eluted by 350 μl H2O and 350 μl methanol. Subsequently, 25 μl of the mixture of methanol and formic acid (50:50, v/v) was applied to extract Oxo twice. The eluted solution was vortex-mixed with 50 μl H2O. Finally, 5 μl of the previously mentioned solutions was injected and analyzed using HPLC-MS/MS.

Pharmacokinetic study

Plasma concentrations of Oxo in 12 tumor patients were determined up to 48 h following single oral administration of a 40-mg S-1 capsule. Blood samples were drawn at various time-points (0.25, 0.5, 1, 1.5, 2, 3, 4, 6, 8, 10, 12, 24 and 48 h) after ingestion of S-1. This clinical pharmacokinetic study was approved by the Ethics Committee of the Affiliated Hospital of the Academy of Military Medical Sciences. All tumor patients provided written informed consent to participate in the study, in accordance with the principles of the Declaration of Helsinki.


Results and Discussion
Selection of IS

It is necessary to use an IS to obtain high accuracy when a mass spectrometer is used as the HPLC detector. [13C2,15N3]-Oxo was adopted as the IS due to the similarities in its retention and ionization characteristics with those of Oxo and the minimal endogenous interferences of [13C2,15N3]-Oxo in the MRM channels.

Chromatography

The stock solutions of Oxo and IS were diluted to a concentration of 1 μg/ml with methanol. The diluted solutions (5 μl) were injected and analyzed by the HPLC-MS/MS method. The mass spectra fragmentation of the ions from Oxo and IS are shown in Fig. 2. Molecular ions of Oxo and IS exhibited m/z 156.0 and 161.1 ([M–H]), respectively. The product ion scan spectra revealed high abundance fragment ions at m/z 111.9 and 117.1 ([M–H]) for Oxo and IS, respectively. Therefore, MRM transitions of m/z 156.0→111.9 and 161.1→117.1 were adopted for quantification of Oxo and IS, respectively. The typical HPLC-MS/MS MRM chromatograms of a blank human plasma sample and a human plasma sample spiked with Oxo and IS at the lower limit of quantification (LOQ; 2.0 ng/ml) are shown in Fig. 3. There was almost no interference peak at the retention time of Oxo (1.66 min) and IS (1.66 min). This result demonstrated that this method was sensitive and specific, allowing for the analysis of samples in batches and exhibiting suitability for pharmacokinetic studies.

Linearity and LOQ

The calibration standards of seven Oxo concentration levels at 2.0, 5.0, 10.0, 25.0, 50.0, 100.0 and 200.0 ng/ml were injected and assayed. The calibration curve was constructed by plotting the peak area ratios (Y) of Oxo to the IS versus the concentrations (X) of Oxo, using weighted least squares linear regression (the weighting factor was 1/X2). In our study, the mean standard curve for Oxo was Y=0.0057X+0.000353 (r=0.9991). The concentrations of Oxo in unknown samples were obtained from the regression line. The LOQ was defined as the lowest concentration on the calibration curve, where precision was within ±20% and accuracy was within ±20%. This was established using six independent samples of standards.

Intra-day and inter-day precision and accuracy

Intra-assay precision and accuracy were assessed by measuring the concentration of Oxo in six aliquots of three different quality control samples, which were extracted and analyzed on the same day. Inter-assay precision and accuracy were determined from the results of three different quality control samples, which were extracted and analyzed six-fold on three consecutive days. The results are presented in Table I.

Matrix effect (ME)

The ME represents the potential ion suppression or enhancement effects of co-eluting and undetected matrix components in plasma. This was obtained by comparing the peak area of Oxo and IS spiked into post-extracted blank plasma samples to that of Oxo and IS spiked into the mobile phase at an equivalent concentration. In this study, the ME was evaluated by three quality control concentrations (5.0, 25.0 and 160.0 ng/ml) of Oxo and an IS concentration level of 250.0 ng/ml. Six samples at each concentration level were analyzed. The blank plasma used in this study was obtained from six different batches. If the peak area ratios were <85 or >115%, an endogenous ME was implied. The ME of plasma at concentrations of 5.0, 25.0 and 160.0 ng/ml were 95.50, 100.45 and 97.61%, respectively. The ME of IS was 95.6%. The results obtained were within the acceptable limit, suggesting that there was no ME observed in this study.

Stability

The stability of Oxo in plasma under various conditions was evaluated. The quality control plasma samples (5.0, 25.0 and 160.0 ng/ml) were stable when placed at room temperature for 4 h, following three freeze/thaw (−40°C) cycles and when stored at −40°C for 3 months. The processed sample, placed in the autosampler at an ambient temperature (20°C) for 2 h, was also stable. These results (Table II) demonstrated that no significant degradation occurred under different conditions.

Pharmacokinetic application

The method was applied for the analysis of plasma samples obtained from 12 tumor patients, following single oral administration of a 40-mg S-1 capsule in the pharmacokinetics study. The pharmacokinetic parameters were estimated by DAS version 2.1.1 software. Pharmacokinetic analysis of Oxo was performed using the noncompartmental method. The concentration maximum (Cmax) and the time to reach it (Tmax) were recorded directly. The elimination rate constant (Ke) was calculated using linear regression of the terminal points from the semi-log plot of plasma concentration against time. The elimination half-life (t1/2) was calculated as 0.693/Ke. The area under the plasma concentration-time curve of Oxo, from time zero to infinity (AUC0-∞), was determined using the linear trapezoidal rule to the last measurable plasma concentration (Ct), plus the additional area from time t to infinity, calculated as Ct/Ke. Finally, the mean plasma concentration versus time profile and pharmacokinetic parameters of Oxo were obtained (Fig. 4; Table III). The primary pharmacokinetic parameters of Oxo in our study were similar to those as previously published (1820). The method developed in this study was demonstrated to be accurate and sensitive when compared with the pharmacokinetic parameters and concentration-time curves of previous studies.

Conclusions

A HPLC-MS/MS method was developed for the determination of Oxo in human plasma. There were numerous advantages to this method, including low volumes of sample requirement, simple sample processing, absence of the ME and a short analysis time. The method was successfully applied to a pharmacokinetic study after single oral administration of a 40-mg S-1 capsule in 12 tumor patients.


References
1.. Kubota T. The role of S-1 in the treatment of gastric cancerBr J Cancer9813011304Year: 200818362933
2.. Shirasaka T,Nakano K,Takechi T,et al. Antitumor activity of 1 M tegafur-0.4 M 5-chloro-2,4-dihydroxypyridine-1 M potassium oxonate (S-1) against human colon carcinoma ortho-topically implanted into nude ratsCancer Res5626022606Year: 19968653704
3.. Blum M,Suzuki A,Ajani JA. A comprehensive review of S-1 in the treatment of advanced gastric adenocarcinomaFuture Oncol6715726Year: 201121675835
4.. Shimoyama S,Kiyokawa T,Nishida M,Seto Y. S-1 monotherapy achieved twenty-month survival for peritoneal lavage cytology-positive gastric cancer patient undergoing noncurative resectionGan To Kagaku Ryoho914111414Year: 2012 (In Japanese).. 22996780
5.. Yamashita T,Arai K,Terashima T,et al. A case report of S-1 monotherapy for advanced hepatocellular carcinomaGan To Kagaku Ryoho914351437Year: 2012 (In Japanese).. 22996786
6.. Iwasa S,Yamada Y,Kato K,Goto A,Honma Y,Hamaguchi T,Shimada Y. Long-term results of a phase II study of S-1 plus irinotecan in metastatic colorectal cancerAnticancer Res941574161Year: 201222993378
7.. Kogashiwa Y,Nagafuji H,Kohno N. Feasibility of concurrent chemoradiotherapy with S-1 administered on alternate days for elderly patients with head and neck cancerAnticancer Res3240354040Year: 201222993356
8.. Shirasaka T,Shimamato Y,Ohshimo H,et al. Development of a novel form of an oral 5-fluorouracil derivative (S-1) directed to the potentiation of the tumor selective cytotoxicity of 5-fluorouracil by two biochemical modulatorsAnticancer Drugs7548557Year: 19968862723
9.. Shirasaka T,Shimamoto Y,Fukushima M. Inhibition by oxonic acid of gastrointestinal toxicity of 5-fluorouracil without loss of its antitumor activity in ratsCancer Res5340044009Year: 19937689420
10.. American Association for Cancer Research86th Annual Meeting: Proceedings36American Association for Cancer ResearchToronto406Year: 1995
11.. Kitamura R,Satoh T,Maeda M,Tsuji A. Enzyme immunoassay of potassium oxonate using specific antibody isolated by immunosorbent gelYakugaku Zasshi114171175Year: 1994 (In Japanese).. 8189354
12.. Matsushima E,Yoshida K,Kitamura R,Yoshida K. Determination of S-1 (combined drug of tegafur, 5-chloro-2,4-dihydroxypyridine and potassium oxonate) and 5-fluorouracil in human plasma and urine using high-performance liquid chromatography and gas chromatography-negative ion chemical ionization mass spectrometryJ Chromatogr B Biomed Sci Appl69195104Year: 19979140762
13.. Schwaninger AE,Meyer MR,Huestis MA,Maurer HH. Development and validation of LC-HRMS and GC-NICI-MS methods for stereoselective determination of MDMA and its phase I and II metabolites in human urineJ Mass Spectrom46603614Year: 201121656610
14.. Liu K,Zhong D,Zou H,Chen X. Determination of tegafur, 5-fluorouracil, gimeracil and oxonic acid in human plasma using liquid chromatography-tandem mass spectrometryJ Pharm Biomed Anal52550556Year: 201020138454
15.. Star-Weinstock M,Williamson BL,Dey S,Pillai S,Purkayastha S. LC-ESI-MS/MS Analysis of Testosterone at Sub-Picogram Levels Using a Novel Derivatization ReagentAnal Chem8493109317Year: 201222994158
16.. Giorgianni F,Mileo V,Desiderio DM,Catinella S,Beranova-Giorgianni S. Characterization of the phosphoproteome in human bronchoalveolar lavage fluidInt J Proteomics2012460261Year: 201222997577
17.. de Mateo S,Estanyol JM,Oliva R. Methods for the analysis of the sperm proteomeMethods Mol Biol927411422Year: 201322992932
18.. Hirata K,Horikoshi N,Aiba K,et al. Pharmacokinetic study of S-1, a novel oral fluorouracil antitumor drugClin Cancer Res520002005Year: 199910473078
19.. Peters GJ,Noordhuis P,Van Kuilenburg AB,et al. Pharmacokinetics of S-1, an oral formulation of ftorafur, oxonic acid and 5-chloro-2,4-dihydroxypyridine (molar ratio 1:0.4:1) in patients with solid tumorsCancer Chemother Pharmacol52112Year: 200312739060
20.. Mende B,Krauss J,Thyssen D,et al. Pharmacokinetic study of S-1Int J Clin Pharmacol Ther476567Year: 200919203542

Article Categories:
  • Articles

Keywords: potassium oxonate, HPLC-MS/MS, pharmacokinetics.

Previous Document:  Emergency focussed assessment with sonography in trauma (FAST) and haemodynamic stability.
Next Document:  A new player in the "synaptopathy" of Alzheimer's disease - arc/arg 3.1.