Document Detail


Development of titanium fixation screw for hydroxyapatite osteosynthesis (APACERAM).
MedLine Citation:
PMID:  18291488     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
BACKGROUND: Cranioplasty using custom-made HAP ceramic implants is a common procedure for skull defects. However, miniplate fixation using commercially available screws to stabilize the HAP flap is associated with several problems due to characteristic brittleness. The authors have thus developed a suitable screw for this procedure. METHODS: Hydroxyapatite blocks (porosity, 40%; thickness, 5 mm) were prepared. Holes were created using a phi 1.4-mm drill. Five types of screw were evaluated for HAP condition after insertion, fixation strength on pull-out test, and fasten plate strength based on maximum torque. RESULTS: Based on this evaluation, the most effective screws were cylindrical style in shape, 4.8 mm in effective length, phi 1.6 mm in effective diameter, and 0.2 mm in edge height. CONCLUSIONS: A novel screw with high fixation potential for the miniplate technique was developed in this study.
Authors:
Yoshihide Tanaka
Related Documents :
1572778 - Repair of lumbar spondylolysis with a hook-screw.
20375778 - Craniocervical fixation with occipital condyle screws: biomechanical analysis of a nove...
3198258 - Herbert screw fixation of osteochondral fractures of the patella.
18638878 - C1-c2 transarticular screw fixation for treatment of c1-c2 instability.
24510068 - Arthroscopic glenoid bone grafting with nonrigid fixation for anterior shoulder instabi...
332748 - Restoration of fractured and hypoplastic incisors by the acid etch resin technique: a t...
Publication Detail:
Type:  Journal Article; Research Support, Non-U.S. Gov't     Date:  2008-03-04
Journal Detail:
Title:  Surgical neurology     Volume:  70     ISSN:  0090-3019     ISO Abbreviation:  Surg Neurol     Publication Date:  2008 Nov 
Date Detail:
Created Date:  2008-10-22     Completed Date:  2008-12-02     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  0367070     Medline TA:  Surg Neurol     Country:  United States    
Other Details:
Languages:  eng     Pagination:  545-9; discussion 549     Citation Subset:  IM    
Affiliation:
Department of Neurosurgery, Yokosuka Kyousai Hospital, Yokosuka, Kanagawa 2380011, Japan. yoshihidet@aol.com
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Biocompatible Materials*
Bone Plates
Bone Screws*
Craniotomy / instrumentation*
Durapatite*
Equipment Design
Fracture Fixation, Internal / instrumentation*
Humans
Materials Testing
Models, Biological
Porosity
Tensile Strength
Titanium*
Chemical
Reg. No./Substance:
0/Biocompatible Materials; 1306-06-5/Durapatite; 7440-32-6/Titanium

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Combined management of intracranial arteriovenous malformations with embolization and gamma knife ra...
Next Document:  Delayed intracerebral hemorrhage after superficial temporal artery-middle cerebral artery anastomosi...