Document Detail


Development of DCGLs By Using Both Probabilistic and Deterministic Analyses in RESRAD (Onsite) and RESRAD-OFFSITE Codes.
MedLine Citation:
PMID:  23528276     Owner:  NLM     Status:  In-Data-Review    
Abstract/OtherAbstract:
The Derived Concentration Guideline Levels for two building areas previously used in waste processing and storage at Argonne National Laboratory were developed using both probabilistic and deterministic radiological environmental pathway analysis. Four scenarios were considered. The two current uses considered were on-site industrial use and off-site residential use with farming. The two future uses (i.e., after an institutional control period of 100 y) were on-site recreational use and on-site residential use with farming. The RESRAD-OFFSITE code was used for the current-use off-site residential/farming scenario and RESRAD (onsite) was used for the other three scenarios. Contaminants of concern were identified from the past operations conducted in the buildings and the actual characterization done at the site. Derived Concentration Guideline Levels were developed for all four scenarios using deterministic and probabilistic approaches, which include both "peak-of-the-means" and "mean-of-the-peaks" analyses. The future-use on-site residential/farming scenario resulted in the most restrictive Derived Concentration Guideline Levels for most radionuclides.
Authors:
Sunita Kamboj; Charley Yu; Robert Johnson
Related Documents :
15833816 - Structural basis for antagonism and resistance of bicalutamide in prostate cancer.
9749416 - Differential binding of estradiol and testosterone to shbg. relation to circulating est...
2342476 - Specific region in hormone binding domain is essential for hormone binding and trans-ac...
10478846 - Androgen specificity of a response unit upstream of the human secretory component gene ...
18094046 - Derlin-1 facilitates the retro-translocation of cholera toxin.
6889136 - Cap binding proteins associated with the nucleus.
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Health physics     Volume:  104     ISSN:  1538-5159     ISO Abbreviation:  Health Phys     Publication Date:  2013 May 
Date Detail:
Created Date:  2013-03-26     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  2985093R     Medline TA:  Health Phys     Country:  United States    
Other Details:
Languages:  eng     Pagination:  S68-75     Citation Subset:  IM    
Affiliation:
*Argonne National Laboratory, Building 240, 9700 South Cass Avenue, Argonne, IL 60439-4832.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Surveyed data for structural shielding calculations of radiographic x-ray installations in Taiwan.
Next Document:  Clearance Monitoring Using Hand-held Devices: Operational Implementation and Challenges.