| Determination of optimal timing window for pulmonary artery MDCT angiography. | |
| | |
MedLine Citation:
|
PMID: 17242236 Owner: NLM Status: MEDLINE |
Abstract/OtherAbstract:
|
OBJECTIVE: The purpose of our study was to determine the optimal timing window for pulmonary artery MDCT angiography. SUBJECTS AND METHODS: We prospectively studied 150 patients. Routine chest CT scans were acquired using 1.3 mL/kg of contrast medium (370 mg I/mL) that was injected at a fixed injection duration of 30 seconds, followed by a 10-second saline chase. To measure early contrast enhancement, sequential monitoring scans were obtained every 2 seconds over a fixed level of the main pulmonary artery 5 seconds after the start of the injection. Then helical diagnostic scans were obtained at three different predetermined scanning delays (group A, 25 seconds; group B, 35 seconds; and group C, 45 seconds after the start of the injection). Time-enhancement curves; time to reach 100 H, 200 H, and peak enhancement; and enhancement duration greater than 200 H of the pulmonary artery were measured from the monitoring scan. Contrast enhancements of the pulmonary artery and descending aorta and vascular artifacts were assessed from the diagnostic scan. RESULTS: Times to reach 100 H and 200 H at the pulmonary artery were mean 11 +/- 2.5 (SD) seconds and 16 +/- 3.0 seconds, respectively. Pulmonary artery enhancement duration of greater than 200 H was 25 +/- 2.7 seconds (only obtained in group C). Mean time to peak enhancement (335 +/- 62 H) at the pulmonary artery was 37 seconds. Mean enhancement measured on the diagnostic scan was 294 +/- 43 H, group A; 208 +/- 48 H, group B; and 157 +/- 15 H, group C for the pulmonary artery, and 240 +/- 42 H, group A; 277 +/- 49 H, group B; and 172 +/- 29 H, group C for the aorta (p < 0.01). Artifacts were noted in the superior vena cava (group A, 96.7%; group B, 18.3%; and group C, 0%) and in the subclavian vein (group A, 93.5%; group B, 38.7%; and group C, 0%), (p < 0.05). CONCLUSION: With our study protocol of a 30-second injection and 10-second saline flush, the optimal temporal window to achieve pulmonary artery enhancement greater than 200 H was from 16 seconds to 41 seconds after the start of the injection. |
| | |
Authors:
|
Chang Hyun Lee; Jin Mo Goo; Hyun Ju Lee; Kwang Gi Kim; Jung-Gi Im; Kyongtae T Bae; C H Lee; J M Goo; H J Lee; K G Kim; J-G Im; K T Bae |
Related Documents
:
|
8586086 - Does dyspnoea during dipyridamole cardiac stress testing indicate bronchospasm and is t... 15466636 - Signaling molecules in overcirculation-induced pulmonary hypertension in piglets: effec... 7259346 - Hemodynamics of leveen shunt pulmonary edema. 9352616 - Inhaled nitric oxide in the neonate with cardiac disease. 21207346 - Unruptured intracranial aneurysms. 10816066 - Percutaneous transradial coronary angiography and angioplasty in patients with occlusiv... |
Publication Detail:
|
Type: Journal Article |
Journal Detail:
|
Title: AJR. American journal of roentgenology Volume: 188 ISSN: 1546-3141 ISO Abbreviation: AJR Am J Roentgenol Publication Date: 2007 Feb |
Date Detail:
|
Created Date: 2007-01-23 Completed Date: 2007-02-20 Revised Date: 2008-02-15 |
Medline Journal Info:
|
Nlm Unique ID: 7708173 Medline TA: AJR Am J Roentgenol Country: United States |
Other Details:
|
Languages: eng Pagination: 313-7 Citation Subset: AIM; IM |
Affiliation:
|
Department of Radiology and Institute of Radiation Medicine, Seoul National University College of Medicine, 28 Yeongeon-dong, Jongno-gu, Seoul 110-744, Korea. |
Export Citation:
|
APA/MLA Format Download EndNote Download BibTex |
| MeSH Terms | |
Descriptor/Qualifier:
|
Adult Aged Aged, 80 and over Angiography / methods* Contrast Media / administration & dosage Female Humans Iohexol / administration & dosage, analogs & derivatives*, diagnostic use Male Middle Aged Pulmonary Artery / radiography* Pulmonary Embolism / radiography* Radiographic Image Enhancement / methods* Reproducibility of Results Sensitivity and Specificity Time Factors Tomography, X-Ray Computed / methods* |
| Chemical | |
Reg. No./Substance:
|
0/Contrast Media; 66108-95-0/Iohexol; 73334-07-3/iopromide |
From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine
Previous Document: Pulmonary nodule volumetric measurement variability as a function of CT slice thickness and nodule m...