Determination of cardiac output and of transcapillary fluid exchange by continuous recording of blood density.
MedLine Citation:
PMID:  7436993     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
We have tested the application of the continuous measurement of the density of the arterial blood for the calculation of the cardiac output and for the determination of the transcapillary fluid exchange. The density of arterial blood was continuously recorded in anesthetized dogs with a mechanical oscillator device (DMA 602 MW built by A. Paar KG, Graz). The time resolution of this device is less than 1 sec, the accuracy is 10(-6) g/ml. Simultaneously the arterial blood temperature was recorded with a thermistor probe. The intravenous injection of isotonic solutions yields temperature and density transients which are of a similar shape and proportional to the injected volume in amplitude. There is a good agreement between the cardiac output calculated from thermodilution transients and from density dilution transients. The injection of hypertonic solutions, e.g. 5% NaCl, 20% mannit or 14.4% urea, into a vein yields arterial density dilution transients which show marked differences and very characteristic features. They can be explained by the assumption of osmotic fluid shifts in the microcirculation of the lung. During the transient of a bolus of hypertonic NaCl or mannit, a transcapillary influx of about 0.170 X 10(-3) ml/sec per mosmols/l and per g wet tissue weight is generated. The effect of hypertonic urea is less by a factor of about 1/2, which is in agreement with the fact that urea diffuses rapidly into the erythrocytes. We conclude that the method of density dilution allows to record and quantify cardiac output and osmotic fluid shifts through the microcirculation of the lung of intact dogs.
Authors:
T Kenner; M Moser; H Hinghofer-Szalkay
Related Documents :
1417293 - Comparison of cardiac output measured by intrapulmonary artery doppler, thermodilution,...
2402213 - Bicycle pedalling forces as a function of pedalling rate and power output.
1417293 - Comparison of cardiac output measured by intrapulmonary artery doppler, thermodilution,...
Publication Detail:
Type:  Journal Article; Research Support, Non-U.S. Gov't    
Journal Detail:
Title:  Basic research in cardiology     Volume:  75     ISSN:  0300-8428     ISO Abbreviation:  Basic Res. Cardiol.     Publication Date:    1980 Jul-Aug
Date Detail:
Created Date:  1981-01-16     Completed Date:  1981-01-16     Revised Date:  2006-11-15    
Medline Journal Info:
Nlm Unique ID:  0360342     Medline TA:  Basic Res Cardiol     Country:  GERMANY, WEST    
Other Details:
Languages:  eng     Pagination:  501-9     Citation Subset:  IM; S    
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Animals
Blood
Blood Pressure
Capillary Permeability*
Cardiac Output*
Carotid Arteries
Dogs
Hematocrit
Models, Cardiovascular
Osmolar Concentration
Temperature

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  An intermittent problem with tibial dyschondroplasia.
Next Document:  Morphological changes accompanying physiological changes in atrial stretch receptors.