Document Detail


Determination of cardiac output from pulse pressure contour during intra-aortic balloon pumping.
MedLine Citation:
PMID:  7444347     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
The reliability of cardiac output determinations from radial pulse pressure contour during intra-aortic balloon pumping (IABP) has been tested and compared with thermodilution measurements. During IABP the pulse pressure curve is distorted by preset volume changes in the aorta. The pressure decrease following balloon deflation was compared with pressure increase following systolic ejection to determine stroke volume and cardiac output. The analysis and calculations were computerized. Measurements were made in thirteen patients with left ventricular failure. The algorithmic analyser failed to produce any results at all in two patients and in ten other patients if failed to produce results more often in some of the patients than others. This made the algorithmic calculation of cardiac output useless in the care of the individual patients. In thirteen patients on IABP seventy-seven comparisons were obtained, and a fair covariation (r = 0.86) was found. The ratio between the two methods of cardiac output measurements did not change significantly with increasing cardiac output.
Authors:
J Høie
Related Documents :
6624937 - Developmental changes in oxygenation and circulatory responses to hypoxemia in lambs.
441697 - Cardiac output and blood pressure at rest and during exercise in boys with bronchial as...
646917 - Haemodynamic responses to induced arterial hypotension in children.
24732917 - Efficacy of chest compressions directed by end-tidal co2 feedback in a pediatric resusc...
9048257 - Association of body mass index, blood pressure and serum levels of triglycerides and hi...
11037747 - Recurrent short-lasting headache associated with paroxysmal hypertension: a clonidine-r...
Publication Detail:
Type:  Comparative Study; Journal Article    
Journal Detail:
Title:  Scandinavian journal of clinical and laboratory investigation     Volume:  40     ISSN:  0036-5513     ISO Abbreviation:  Scand. J. Clin. Lab. Invest.     Publication Date:  1980 Sep 
Date Detail:
Created Date:  1981-02-26     Completed Date:  1981-02-26     Revised Date:  2006-11-15    
Medline Journal Info:
Nlm Unique ID:  0404375     Medline TA:  Scand J Clin Lab Invest     Country:  NORWAY    
Other Details:
Languages:  eng     Pagination:  445-9     Citation Subset:  IM    
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Assisted Circulation / methods*
Blood Pressure
Cardiac Output*
Humans
Intra-Aortic Balloon Pumping / methods*
Monitoring, Physiologic / methods
Pulse*
Stroke Volume
Thermodilution

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Assessment of cerebral injury with spinal fluid creatine kinase (CSF-CK) in patients after cardiac r...
Next Document:  Body composition. Prediction of normal body potassium, body water and body fat in adults on the basi...