Conventional determination of the ventricular effective refractory period (VERP) is unsuitable for detection of rapid fluctuations in the effective refractory period (ERP). A programmed stimulation system was developed that adapts continuous atrioventricular sequential pacing, incremental extrastimulus interval (S1S2) scanning, and automatic detection of extrastimulus capture which is followed by shortening of S1S2 to execute repeated scanning. The accuracy of ERP determination was tested using variable incremental (2 and 4 ms) and decremental (4-16 ms) steps of the S1S2 interval. Based on a mean of 82 determinations in eight patients, the average VERP values stayed at 249.8-251.0 ms except during the highest capture frequency. Standard deviation of ERP values ranged from 1.1 to 2.5 ms on average at the tested incremental and decremental steps. One determination was accomplished within 7.8-15.6 seconds on average. The ability to track changes in ERP was tested by changing the drive cycle length. Time constants for the adaptation rate of VERP and ventricular monophasic action potential duration at a 90% level of repolarization were determined from each test, and were similar, 51 +/- 8 seconds (mean +/- SEM) for ERP and 51 +/- 6 seconds for the action potential duration. Thus, the developed method provides accurate ERP measurements during rapid variation in ventricular refractoriness. It allows studying the recovery of excitability and the action potential duration simultaneously, and would be valuable particularly in pathological conditions and pharmacologic interventions where these electrophysiological variables become dissociated.
Authors:
Lauri Toivonen; Eija Kettunen; Kim Simelius; Hannu Parikka
Related Documents :
7044469 - Effects of anaerobic and microaerophilic conditions of extraction and incubation on the...
9861609 - A new reliable laboratory test of endurance performance for road cyclists.
19687309 - Exertional dysnatremia in collapsed marathon runners: a critical role for point-of-care...
18685519 - A 3-min all-out cycling test is sensitive to a change in critical power.
12200919 - Prediction of 2000 m indoor rowing performance using a 30 s sprint and maximal oxygen u...
8724469 - Sensitivity of the jamar dynamometer in detecting submaximal grip effort.
5764249 - Oral calcium-loading test in infancy, with particular reference to idiopathic hypercalc...
15667109 - Reliability of a commercial kit to test groundwater for arsenic in bangladesh.
7430369 - Elisa for toxoplasma antibody detection: a comparison with other serodiagnostic tests.
Publication Detail:
Type:  Comparative Study; Journal Article    
Journal Detail:
Title:  Pacing and clinical electrophysiology : PACE     Volume:  25     ISSN:  0147-8389     ISO Abbreviation:  Pacing Clin Electrophysiol     Publication Date:  2002 Mar 
Date Detail:
Created Date:  2002-05-06     Completed Date:  2002-12-12     Revised Date:  2006-11-15    
Medline Journal Info:
Nlm Unique ID:  7803944     Medline TA:  Pacing Clin Electrophysiol     Country:  United States    
Other Details:
Languages:  eng     Pagination:  300-7     Citation Subset:  IM    
Affiliation:
Division of Cardiology, Helsinki University Hospital, Finland. lauri.toivonen@hus.fi
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Action Potentials
Adult
Aged
Cardiac Pacing, Artificial / methods*
Electrophysiology
Female
Heart Conduction System / physiology*
Humans
Male
Middle Aged
Myocardial Contraction / physiology*
Ventricular Function / physiology*

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Transient proarrhythmic state following atrioventricular junctional radiofrequency ablation.
Next Document:  Progressive isthmus delay during atrial flutter ablation: the critical importance of isthmus spannin...