Endotracheal intubation is a frequently performed procedure in the prehospital setting, intensive care unit, and for patients undergoing surgery. The endotracheal tube cuff must be inflated to a pressure that prevents air leaks without compromising tracheal mucosal blood flow. For simultaneous endotracheal tube cuff inflation and measurement, we designed and tested a novel pressure-sensing syringe in vitro. The prototype was developed using a standard 10-mL polycarbonate syringe body that houses a plunger and a silicone rubber bellows, the pressure-sensing element. Bellow feasibility was determined and modeled using finite element analysis. Actual pressure measurement repeatability at each pressure measurement for each bellows (pressure versus deflection) was within an average standard deviation of 0.3 cm to 1.61 cm (1%-5% error). Using an aneroid manometer for comparison, there was excellent linear correlation with a Spearman rank of 0.99 (P < 0.001), up to 30 cm H(2)O.
Authors:
Alexander H Slocum; Alexander H Slocum; Joan E Spiegel
Related Documents :
22979477 - Sound radiation of double rotating dipole.
3488137 - The dynamics of blood pressure in populations and hypertensive cohorts.
12419177 - Hypertension and the eye.
25381467 - Isolated patellofemoral arthroplasty reproduces natural patellofemoral joint kinematics...
7554427 - Spectral analysis of systolic blood pressure and heart rate oscillations related to res...
2661427 - Erythrocyte sodium transport and blood pressure in white subjects.
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2012-4-4
Journal Detail:
Title:  Anesthesia and analgesia     Volume:  -     ISSN:  1526-7598     ISO Abbreviation:  -     Publication Date:  2012 Apr 
Date Detail:
Created Date:  2012-4-11     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  1310650     Medline TA:  Anesth Analg     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Affiliation:
From the *Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge; and.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Life cycle greenhouse gas emissions of anesthetic drugs.
Next Document:  Hemoglobin Desaturation After Propofol/Remifentanil-Induced Apnea: A Study of the Recovery of Sponta...