| Delayed perforation of the right ventricle as a complication of permanent cardiac pacing - is following the guidelines always the right choice? Non-standard treatment - a case report and literature review. | |
| | |
MedLine Citation:
|
PMID: 20411465 Owner: NLM Status: MEDLINE |
Abstract/OtherAbstract:
|
A case of a delayed perforation of the right ventricle by the pacemaker lead in a 67-year-old woman is presented. Perforation, mimicking stenocardial symptoms, was incidentally diagnosed on a computed tomography chest scan. Percutaneous lead extraction was successfully performed, with simultaneous implantation of a new pacemaker lead. |
| | |
Authors:
|
Anna Rydlewska; Barbara Małecka; Andrzej Zabek; Piotr Klimeczek; Jacek Lelakowski; Mieczysław Pasowicz; Marek Czajkowski; Andrzej Kutarski |
Related Documents
:
|
11754225 - True aneurysm of the left ventricle: a case report and literature review. 20632955 - Takotsubo cardiomyopathy. 12545345 - Heart enlargement after thrombolysis for unsuccessful resuscitation. 22230355 - Malaria control in bhutan: a case study of a country embarking on elimination. 22114445 - Ectopic eruption - a review and case report. 9420085 - Diagnostic and microsurgical presentation of intracranial angiolipomas. case report and... |
Publication Detail:
|
Type: Case Reports; Journal Article; Review |
Journal Detail:
|
Title: Kardiologia polska Volume: 68 ISSN: 0022-9032 ISO Abbreviation: Kardiol Pol Publication Date: 2010 Mar |
Date Detail:
|
Created Date: 2010-04-22 Completed Date: 2010-07-13 Revised Date: - |
Medline Journal Info:
|
Nlm Unique ID: 0376352 Medline TA: Kardiol Pol Country: Poland |
Other Details:
|
Languages: eng Pagination: 357-61 Citation Subset: IM |
Affiliation:
|
Department of Electrocardiology, The John Paul II Hospital, Krakow. |
Export Citation:
|
APA/MLA Format Download EndNote Download BibTex |
| MeSH Terms | |
Descriptor/Qualifier:
|
Aged Cardiac Pacing, Artificial / adverse effects Delayed Diagnosis Device Removal Diagnosis, Differential Diagnostic Errors* Female Guideline Adherence* Heart Injuries / diagnosis*, etiology* Heart Ventricles / injuries* Humans Pacemaker, Artificial / adverse effects* Pericardial Effusion / diagnosis, etiology Practice Guidelines as Topic Tomography, X-Ray Computed |
| Comments/Corrections | |
Comment In:
|
Kardiol Pol. 2010 Mar;68(3):362-3
[PMID:
20491183
]
|
From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine
Previous Document: The Bland-White-Garland syndrome detected during qualification for surgery, due to significant mitra...
Next Document: CT2TEE - a novel, internet-based simulator of transoesophageal echocardiography in congenital heart ...