Document Detail


Defibrillator patch electrode constriction: an underrecognized entity.
MedLine Citation:
PMID:  7574964     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Pericardial constriction associated with the placement of intrapericardial defibrillator patches is a rare occurrence that is reported only one tenth as often in defibrillator patients as in patients undergoing other types of cardiac operations. Although this discrepancy may be attributable to a lower incidence of constriction with the defibrillator patch electrode procedure, it may also indicate a failure to recognize that progressive right heart failure and signs of low cardiac output that could be due to pericardial constriction and not progressive systolic dysfunction. Because surgical removal of the patches and decortication of the epicardial surface is the only effective therapy, it is important to recognize this uncommon, but profoundly debilitating entity.
Authors:
W W Barrington; U Deligonul; A R Easley; J R Windle
Related Documents :
22308084 - Clinical implication of right ventricular to left ventricular interlead sensed electric...
19378914 - Aed use in a passenger during a long-haul flight: repeated defibrillation with a succes...
6869564 - Improved defibrillator waveform safety factor with biphasic waveforms.
1182974 - Emergency care.
15921804 - Echo-doppler and clinical evaluations to define hemodynamic profile in patients with ch...
12383404 - The emerging role of induced hypothermia in the management of acute stroke.
Publication Detail:
Type:  Case Reports; Journal Article; Review    
Journal Detail:
Title:  The Annals of thoracic surgery     Volume:  60     ISSN:  0003-4975     ISO Abbreviation:  Ann. Thorac. Surg.     Publication Date:  1995 Oct 
Date Detail:
Created Date:  1995-11-08     Completed Date:  1995-11-08     Revised Date:  2005-11-16    
Medline Journal Info:
Nlm Unique ID:  15030100R     Medline TA:  Ann Thorac Surg     Country:  UNITED STATES    
Other Details:
Languages:  eng     Pagination:  1112-5; discussion 1115-6     Citation Subset:  AIM; IM    
Affiliation:
Department of Internal Medicine, University of Nebraska Medical Center, Omaha, 68198-2265, USA.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Adult
Constriction, Pathologic
Defibrillators, Implantable / adverse effects*
Female
Heart Diseases / diagnosis,  etiology*
Humans
Pericardium*
Comments/Corrections
Comment In:
Ann Thorac Surg. 1996 Mar;61(3):1042   [PMID:  8619688 ]

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Paradoxical embolism in the presence of right-to-left shunt due to tricuspid occlusion.
Next Document:  Umbilical artery flow velocity during maternal cardiopulmonary bypass.