Decontamination of blood soaked electronic devices using ultrasonic technology.
MedLine Citation:
PMID:  21820828     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
With advancements in technology allowing for the miniaturization of consumer electronics, criminal investigations of all types frequently involve the forensic examination of electronic devices, such as cellular telephones, smartphones, and portable flash memory; in some extreme, violent cases, these devices are found covered in blood. Due to the complexity of such devices, standard operating procedures for the complete removal of blood had not previously been established by the Royal Canadian Mounted Police prior to this study. The electronics industry has adopted the use of the ultrasonic cleaner for sanitizing printed circuit boards (PCBs) by removing residues and contaminants. High frequency sound waves created by the machine penetrate and remove dirt and residues; however, early research during the 1950s recorded these sound waves breaking the internal bonds of integrated circuit chips. Experimentation with modern ultrasonic technology was used to determine if internal components were damaged, as well as if ultrasonic cleaning was the most suitable method for the removal of dried and liquid blood from a PCB. Several disinfectant solutions were compared against the 0.5% Triton(®) X-100 detergent solution in the ultrasonic cleaner, including: 10% sodium hypochlorite bleach, 85% isopropyl alcohol, and Conflikt(®) disinfectant spray. The results not only demonstrated that the ultrasonic cleaner did not damage the vital memory chip on the PCB, but also, with the assistance of Conflikt(®), was able to remove all traces of blood as indicated by Hemastix(®) reagent strips. Of five methods experimented with, two cycles of ultrasonic cleaning followed by sanitization with Conflikt(®) proved to be the only procedure capable of removing all traces of blood, as confirmed with both Hemastix(®) reagent strips and the hemochromogen test.
Authors:
Kimberly C Dudeck; Tamara C Brennan; Daniel J Embury
Related Documents :
2379388 - Single and multiple doses of oral cimetidine do not change liver blood flow in humans.
10379498 - Is the liver of the fetus the 4th preferential organ for arterial blood supply besides ...
15448318 - Nature of doppler perfusion index changes in patients with colorectal cancer liver meta...
2309148 - Hepatic blood flow and splanchnic oxygen consumption measurements in clinical sepsis.
12669168 - The role of vision in maintaining heading direction: effects of changing gaze and optic...
18348868 - Evaluation of sysmex uf-1000i for use in cerebrospinal fluid analysis.
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2011-8-4
Journal Detail:
Title:  Forensic science international     Volume:  -     ISSN:  1872-6283     ISO Abbreviation:  -     Publication Date:  2011 Aug 
Date Detail:
Created Date:  2011-8-8     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  7902034     Medline TA:  Forensic Sci Int     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Copyright Information:
Crown Copyright © 2011. Published by Elsevier Ireland Ltd. All rights reserved.
Affiliation:
Royal Canadian Mounted Police (RCMP) Technological Crime Branch (TCB), 1426 St. Joseph Blvd., Ottawa, ON K1A 0R2, Canada.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Diet and social disadvantage: The 'Medical Home' improves nutrition in childhood and diminishes like...
Next Document:  Dose modulated retrospective ECG-gated versus non-gated 64-row CT angiography of the aorta at the sa...