Document Detail


Day-to-Day Reproducibility of Prostate Intrafraction Motion Assessed by Multiple kV and MV Imaging of Implanted Markers During Treatment.
MedLine Citation:
PMID:  22019244     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
PURPOSE: When one is performing online setup correction for prostate positioning displacements prior to daily dose delivery, intrafraction motion can become a limiting factor to prostate targeting accuracy. The aim of this study was to quantify and characterize prostate intrafraction motion assessed by multiple kilovoltage (kV) and megavoltage (MV) imaging of implanted markers during treatment in a large patient group. METHODS AND MATERIALS: Intrafraction motion in the sagittal plane was studied by retrospective analysis of displacements of implanted gold markers on (nearly) lateral kV and MV images obtained at various time points during the treatment fractions (mean, 27 per patient) in 108 consecutive patients. The effective prostate motion in a fraction was defined as the time-weighted mean displacement. RESULTS: Prostate displacements in the sagittal plane increased during the fraction (mean, 0.2 ± 0.2 mm/min). Forty percent of patients had a systematic (i.e., appearing in all fractions) effective displacement in the sagittal plane greater than 2 mm. Observed effective population mean-of-means (μeff) +/- systematic (Σeff) intrafraction motion (μ(eff) ± Σ(eff)) was 0.9 ± 1.1 mm and 0.6 ± 1.0 mm for the anterior-posterior and superior inferior directions, respectively. Corresponding random motion (σ(eff)) was 1.2 mm and 1.1 mm. Mean effective prostate motion in the first 5 fractions was predictive for mean effective displacement in the remaining fractions (p < 0.001). CONCLUSION: For a large subgroup of patients, the systematic component of intrafraction prostate motion was substantial. Intrafraction motion correction prior to each beam delivery or offline corrections could likely be beneficial for the subgroup of patients with significant motion. The systematic component is well predicted by measurements in the initial fractions.
Authors:
Theodore F Mutanga; Hans C J de Boer; Vinayakrishnan Rajan; Maarten L P Dirkx; Luca Incrocci; Ben J M Heijmen
Related Documents :
20141054 - The influence of low-frequency magnetic field on plasma antioxidant capacity and heart ...
20700194 - Light hazards to the patient's retina from ophthalmic instruments.
17961634 - Development of a new biomonitoring method to detect the abnormal activity of daphnia ma...
1787254 - Effects of nosocusis, and industrial and gun noise on hearing of u.s. adults.
11497564 - Rectification by hopping motion through nonsymmetric potentials: local versus global bias.
23986874 - Ocular vestibular evoked myogenic potential using different test stimuli.
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2011-10-20
Journal Detail:
Title:  International journal of radiation oncology, biology, physics     Volume:  -     ISSN:  1879-355X     ISO Abbreviation:  -     Publication Date:  2011 Oct 
Date Detail:
Created Date:  2011-10-24     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  7603616     Medline TA:  Int J Radiat Oncol Biol Phys     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Copyright Information:
Copyright © 2011 Elsevier Inc. All rights reserved.
Affiliation:
Department of Radiation Oncology, Erasmus MC-Daniel den Hoed Cancer Center, Rotterdam, The Netherlands.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Concurrent radiotherapy and gemcitabine for unresectable pancreatic adenocarcinoma: impact of adjuva...
Next Document:  Stereotactic Radiosurgery for Recurrent or Unresectable Pilocytic Astrocytoma.