Document Detail


Cutting balloon angioplasty versus standard balloon angioplasty for failing infra-inguinal vein grafts: comparative study of short- and mid-term primary patency rates.
MedLine Citation:
PMID:  17393055     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
PURPOSE: To evaluate the results of a recent change in practice in our institution using cutting balloon angioplasty instead of standard balloon angioplasty as the primary treatment for failing infra-inguinal vein bypass grafts. METHODS: In this nonrandomized cohort study with a historical control, failing infra-inguinal vein grafts were identified at duplex surveillance or clinical examination. Patients had confirmatory arteriography and balloon angioplasty at the same attendance. Interventions proximal or distal to the graft itself and prosthetic grafts were not included. Patients were entered into a duplex graft surveillance program. Initial assessment of technical success was duplex or improvement 4-6 weeks after the primary angioplasty. RESULTS: Twenty-seven consecutive patients were treated with standard balloon angioplasty, then 11 consecutive patients were treated with cutting balloon angioplasty. Initial technical success was 74% for the standard balloon versus 82% for the cutting balloon. The primary patency rate at 6 months was 16/26 (62%) for standard balloon angioplasty and 8/10 (80%) for cutting balloon angioplasty (p = 0.44). The primary patency rate at 12 months was 9/25 (36%) for standard balloon angioplasty and 5/10 (50%) for cutting balloon angioplasty (p = 0.47). CONCLUSION: The use of cutting balloons for primary angioplasty of infra-inguinal vein grafts offers no definite advantage over standard balloon angioplasty in this institution or compared with patency rates after standard balloon angioplasty reported elsewhere. Larger multicenter studies would be required to demonstrate whether there was any real difference between the two techniques.
Authors:
Raghunandan Vikram; Rose A Ross; Rajesh Bhat; Gareth D Griffiths; Peter A Stonebridge; J Graeme Houston; S Chakraverty
Related Documents :
12134975 - Angioplasty induced myocardial ischaemia prolongs the signal-averaged p-wave duration i...
6225735 - The case for early direct myocardial reperfusion.
7978505 - Long-term follow-up after peripheral and coronary angioplasty in patients undergoing bo...
8138335 - Late symptom recurrence after successful coronary angioplasty: angiographic outcome.
12963235 - Aorto-right atrial fistula.
3886055 - Transcutaneous oxygen tension as an index of maturity in hypertrophic scars treated by ...
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Cardiovascular and interventional radiology     Volume:  30     ISSN:  0174-1551     ISO Abbreviation:  Cardiovasc Intervent Radiol     Publication Date:    2007 Jul-Aug
Date Detail:
Created Date:  2007-08-16     Completed Date:  2007-11-30     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  8003538     Medline TA:  Cardiovasc Intervent Radiol     Country:  United States    
Other Details:
Languages:  eng     Pagination:  607-10     Citation Subset:  IM    
Affiliation:
Department of Diagnostic Imaging, M.D. Anderson Cancer Center, 1515 Holcombe Boulevard, Houston, TX 77030, USA.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Aged
Aged, 80 and over
Angiography
Angioplasty, Balloon / instrumentation*
Female
Femoral Artery / surgery*
Follow-Up Studies
Graft Occlusion, Vascular / diagnosis,  therapy*
Humans
Ischemia / therapy*
Leg / blood supply*
Male
Middle Aged
Popliteal Artery / surgery*
Recurrence
Ultrasonography, Doppler, Duplex
Vascular Patency / physiology

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Black band disease microbial community variation on corals in three regions of the wider Caribbean.
Next Document:  The proximal radial artery perforator flap (PRAP-flap): an anatomical study for its use in elbow rec...