Current uses of transfusion administration sets: a cause for concern?
MedLine Citation:
PMID:  20553428     Owner:  NLM     Status:  In-Process    
Abstract/OtherAbstract:
There is potential for inappropriate use of transfusion administration sets when used in combination with modern infusion pumps with consequences for patient safety. The aims of our study were to (i) establish if the design and testing of transfusion sets specified in International Standard ISO 1135-4 are adequate for their current applications, (ii) identify if infusion pumps currently supplied in the UK for blood component administration are suitable for this purpose and (iii) determine the additional control measures needed to be applied by manufacturers and users to ensure patient safety. Keyword literature search was carried out to review and correlate important transfusion parameters with resultant adverse effects. Units for occlusion pressure, flow rate and haemolysis were standardised for ease of comparison. A sample of transfusion set instructions for use was reviewed. Principal suppliers of infusion pumps to the UK market were surveyed to identify those sold for blood transfusion, their recommended operating parameters and compatible transfusion sets. Previous work showed clinically unacceptable haemolysis at pressures above 40 kPa. Modern infusion pumps operate under negative pressures of up to 210 kPa. ISO 1135-4 design and test requirements do not match this performance and in particular omit testing under negative pressure. Transfusion sets surveyed did not indicate flow or pressure restrictions or specify the blood components with which they had been validated. ISO 1135-4 requires updating and has been initiated. Meanwhile, recommendations are made for transfusion set manufacturers concerning pressure limitations and restrictions on blood component type and for users concerning purchase, configuration and validation of infusion pumps and disposables.
Authors:
M J Nightingale; D R Norfolk; D J Pinchon
Related Documents :
996818 - A simple cooling circuit for topical cardiac hypothermia.
7164228 - Control system for circulatory assist devices: determination of suitable control variab...
8486418 - Chronic in vivo function of a new ventricular assist device: the extracorporeal pulsati...
1986568 - Inaccurate blood flow rate during rapid hemodialysis.
12226038 - Comparison of sputum induction using high-output and low-output ultrasonic nebulizers i...
71508 - On the inappropriate in hypertension research.
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Transfusion medicine (Oxford, England)     Volume:  20     ISSN:  1365-3148     ISO Abbreviation:  Transfus Med     Publication Date:  2010 Oct 
Date Detail:
Created Date:  2010-11-05     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  9301182     Medline TA:  Transfus Med     Country:  England    
Other Details:
Languages:  eng     Pagination:  291-302     Citation Subset:  IM    
Copyright Information:
© 2010 The Authors. Transfusion Medicine © 2010 British Blood Transfusion Society.
Affiliation:
NHS Blood and Transplant, Southampton, UK. mark.nightingale@nbs.nhs.uk
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Prevalence, serologic and genetic studies of high expressers of the blood group A antigen on platele...
Next Document:  Distribution of the human platelet alloantigen Cab(a) allele in the Chinese Han population.