Correction for partial volume effects in PET: principle and validation.
MedLine Citation:
PMID:  9591599     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
The accuracy of PET for measuring regional radiotracer concentrations in the human brain is limited by the finite resolution capability of the scanner and the resulting partial volume effects (PVEs). We designed a new algorithm to correct for PVEs by characterizing the geometric interaction between the PET system and the brain activity distribution. METHODS: The partial volume correction (PVC) algorithm uses high-resolution volumetric MR images correlated with the PET volume. We used a PET simulator to calculate recovery and cross-contamination factors of identified tissue components in the brain model. These geometry-dependent transfer coefficients form a matrix representing the fraction of true activity from each distinct brain region observed in any given set of regions of interest. This matrix can be inverted to correct for PVEs, independent of the tracer concentrations in each tissue component. A sphere phantom was used to validate the simulated point-spread function of the PET scanner. Accuracy and precision of the PVC method were assessed using a human basal ganglia phantom. A constant contrast experiment was performed to explore the recovery capability and statistic error propagation of PVC in various noise conditions. In addition, a dual-isotope experiment was used to evaluate the ability of the PVC algorithm to recover activity concentrations in small structures surrounded by background activity with a different radioactive half-life. This models the time-variable contrast between regions that is often seen in neuroreceptor studies. RESULTS: Data from the three-dimensional brain phantom demonstrated a full recovery capability of PVC with less than 10% root mean-square error in terms of absolute values, which decreased to less than 2% when results from four PET slices were averaged. Inaccuracy in the estimation of 18F tracer half-life in the presence of 11C background activity was in the range of 25%-50% before PVC and 0%-6% after PVC, for resolution varying from 6 to 14 mm FWHM. In terms of noise propagation, the degradation of the coefficient of variation after PVC was found to be easily predictable and typically on the order of 25%. CONCLUSION: The PVC algorithm allows the correction for PVEs simultaneously in all identified brain regions, independent of tracer levels.
Authors:
O G Rousset; Y Ma; A C Evans
Related Documents :
20102109 - Advances in imaging low-grade gliomas.
12483429 - Diagnostic utility of fdg pet in multiple myeloma.
11083539 - Diagnosis of myocardial viability by dual-head coincidence gamma camera fluorine-18 flu...
18342769 - Diagnostic performance of positron emission tomography in the detection of coronary art...
14646039 - Assessment of cancer-associated biomarkers by positron emission tomography: advances an...
17475959 - Pet/ct of skull base meningiomas using 2-18f-fluoro-l-tyrosine: initial report.
12173019 - Clinical role of (18)f-fdg pet for initial staging of patients with extrahepatic bile d...
15710159 - Repeat ct scan in closed head injury.
21944189 - The role of fdg pet-ct in differential diagnosis of pleural pathologies.
Publication Detail:
Type:  Journal Article; Research Support, Non-U.S. Gov't    
Journal Detail:
Title:  Journal of nuclear medicine : official publication, Society of Nuclear Medicine     Volume:  39     ISSN:  0161-5505     ISO Abbreviation:  J. Nucl. Med.     Publication Date:  1998 May 
Date Detail:
Created Date:  1998-06-11     Completed Date:  1998-06-11     Revised Date:  2006-11-15    
Medline Journal Info:
Nlm Unique ID:  0217410     Medline TA:  J Nucl Med     Country:  UNITED STATES    
Other Details:
Languages:  eng     Pagination:  904-11     Citation Subset:  IM    
Affiliation:
McConnell Brain Imaging Center, Montréal Neurological Institute, McGill University, Québec, Canada.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Algorithms*
Brain / radionuclide imaging*
Carbon Radioisotopes / diagnostic use
Computer Simulation
Fluorine Radioisotopes / diagnostic use
Humans
Image Processing, Computer-Assisted / methods
Phantoms, Imaging
Tomography, Emission-Computed / instrumentation,  methods*
Chemical
Reg. No./Substance:
0/Carbon Radioisotopes; 0/Fluorine Radioisotopes

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  In vitro demonstration of synergy between radionuclide and chemotherapy.
Next Document:  Use of stabilized technetium-99m-exametazime for radiolabeling leukocytes.