Document Detail


Contrast enhancement in chest multidetector computed tomography: intraindividual comparison of 300 mg/ml versus 400 mg/ml iodinated contrast medium.
MedLine Citation:
PMID:  19124099     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
RATIONALE AND OBJECTIVES: We sought to intraindividually compare intravascular contrast enhancement in multidector computed tomography (MDCT) of the chest using contrast media (CM) containing 300 and 400 mg iodine/ml. MATERIALS AND METHODS: Seventy-one patients underwent repeated MDCT scanning of the chest at baseline and follow-up. CM with standard iodine (protocol A: 300 mg iodine/ml; Iopromide 300) and high iodine concentration (protocol B: 400 mg iodine/ml; Iomeprol 400) were used. The iodine delivery rate (1.29 g iodine/s) and total iodine load (37 g iodine) were identical for the two protocols. Contrast enhancement was measured in the right and left ventricles, pulmonary trunk, right and left pulmonary arteries, and ascending and descending aortas. Results were compared using paired t-tests; P values were adjusted using Bonferroni correction (P <or= .005). RESULTS: Contrast enhancement values showed no statistically significant differences between the two protocols at all anatomic sites (all P > .005). In the right ventricle, pulmonary trunk, and right and left pulmonary arteries, higher attenuation values for protocol A were detected compared to protocol B (379.0 +/- 110.5 vs. 349.8 +/- 117.6, 354.5 +/- 112.2 vs 330.9 +/- 118.3, 348.6 +/- 106.0 vs. 321.8 +/- 109.9, and 347.9 +/- 102.4 vs. 321.0 +/- 104.9 HU, respectively). After the lung circulation (left ventricle, ascending aorta, and descending aorta), attenuation values were marginally higher for protocol B. Using both protocols resulted in suitable contrast enhancement with a mean pulmonary attenuation higher than 300 HU. CONCLUSIONS: Using an adapted injection protocol, the administration of 300 and 400 mg iodine CM resulted in a suitable intravascular contrast enhancement in the chest. The use of 400 mg iodine CM does not lead to a statistically significant improvement in contrast enhancement compared to the 300 mg iodine CM.
Authors:
Florian F Behrendt; Cedric Plumhans; Sebastian Keil; Georg Mühlenbruch; Marco Das; Peter Seidensticker; Christina Mutscher; Rolf W Günther; Andreas H Mahnken
Related Documents :
6489259 - Effects of chronic administration of amiodarone on kinetics of metabolism of iodothyron...
19053029 - Iodine-131 therapy for hyperthyroidism prescribed by endocrinologist - our preliminary ...
1835589 - Long-term effects in skin and thyroid after radiotherapy for skin angiomas: a french re...
2481769 - Rat heart thyroxine 5'-deiodinase is sensitively depressed by amiodarone.
3988239 - Low doses of t3 induce a rapid metabolic response in young lambs.
7887519 - Prospective randomized comparison of intravenous versus subcutaneous administration of ...
15817219 - Acaricidal properties of the essential oil of melaleuca alternifolia cheel (tea tree oi...
1655549 - Priming interactions between platelet activating factor and histamine in the in vivo mi...
2754099 - Topically applied ivermectin: efficacy against torsalo (diptera: cuterebridae).
Publication Detail:
Type:  Comparative Study; Controlled Clinical Trial; Journal Article    
Journal Detail:
Title:  Academic radiology     Volume:  16     ISSN:  1878-4046     ISO Abbreviation:  Acad Radiol     Publication Date:  2009 Feb 
Date Detail:
Created Date:  2009-01-06     Completed Date:  2009-03-09     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  9440159     Medline TA:  Acad Radiol     Country:  United States    
Other Details:
Languages:  eng     Pagination:  144-9     Citation Subset:  IM    
Affiliation:
Department of Diagnostic Radiology, University Hospital RWTH Aachen, Aachen, Germany. behrendt@rad.rwth-aachen.de
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Adult
Aged
Aged, 80 and over
Contrast Media / administration & dosage*
Dose-Response Relationship, Drug
Female
Humans
Iopamidol / administration & dosage,  analogs & derivatives*
Male
Middle Aged
Radiographic Image Enhancement / methods*
Radiography, Thoracic / methods*
Reproducibility of Results
Sensitivity and Specificity
Tomography, X-Ray Computed / methods*
Chemical
Reg. No./Substance:
0/Contrast Media; 62883-00-5/Iopamidol; 78649-41-9/iomeprol

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Prophylactic vertebroplasty: cement injection into non-fractured vertebral bodies during percutaneou...
Next Document:  Helical multidetector row quantitative computed tomography (QCT) precision.