Continuous ultrasonic monitoring of balloon valvuloplasty.
MedLine Citation:
PMID:  12047784     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
A novel ultrasound transducer developed in our laboratory (CONTISON) was used for monitoring catheter balloon commissurotomy (CBC). The transducer was placed at the cardiac apex to obtain an apical four-chamber view and attached to the chest wall using an adhesive ring. During the procedure, the tip of the needle was imaged first in the right atrium and was seen to traverse the interatrial septum and enter the left atrium. Mitral valve gradients were measured before and after CBC.
Authors:
Arash Vahdat; Srihdar Vijayasekaran; Alex Durairaj; Anil Mehra; P A N Chandraratna
Related Documents :
6242044 - The long wire technique--a new technique for steerable balloon catheter dilatation of c...
8515574 - Reduction of thrombogenicity with argon laser angioplasty. comparison with balloon angi...
6717054 - Paraplegia following percutaneous insertion of an intra-aortic balloon.
6659004 - Paraplegia associated with intraaortic balloon pump counterpulsation.
12428664 - Scanning electron microscopy of vascular corrosion casts and histologic examination of ...
18482844 - Incidence and pathophysiology of atrioventricular block following mitral valve replacem...
Publication Detail:
Type:  Case Reports; Journal Article    
Journal Detail:
Title:  Echocardiography (Mount Kisco, N.Y.)     Volume:  19     ISSN:  0742-2822     ISO Abbreviation:  Echocardiography     Publication Date:  2002 May 
Date Detail:
Created Date:  2002-06-05     Completed Date:  2002-07-23     Revised Date:  2007-11-15    
Medline Journal Info:
Nlm Unique ID:  8511187     Medline TA:  Echocardiography     Country:  United States    
Other Details:
Languages:  eng     Pagination:  325-8     Citation Subset:  IM    
Affiliation:
Department of Cardiology, LAC and USC Medical Center, Los Angeles, CA, USA.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Adult
Balloon Dilatation*
Blood Flow Velocity
Echocardiography / methods*
Female
Heart Failure / ultrasonography
Humans
Mitral Valve Stenosis / therapy,  ultrasonography*
Monitoring, Physiologic / methods*
Transducers

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Prevalence and clinical significance of left atrial spontaneous echo contrast detected by transesoph...
Next Document:  Constrictive pericarditis localized to left ventricle presented with left pleural effusion: a case r...