Continuous on-line monitoring of left ventricular function with a new nonimaging detector:validation and clinical use in the evaluation of patients post angioplasty.
MedLine Citation:
PMID:  2035375     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
A new miniaturized nonimaging radionuclide detector (Cardioscint, Oxford, England) was evaluated for the continuous on-line assessment of left ventricular function. This cesium iodide probe can be placed on the patient's chest and can be interfaced to an IBM compatible personal computer conveniently placed at the patient's bedside. This system can provide a beat-to-beat or gated determination of left ventricular ejection fraction and ST segment analysis. In 28 patients this miniaturized probe was correlated against a high resolution gamma camera study. Over a wide range of ejection fraction (31% to 76%) in patients with and without regional wall motion abnormalities, the correlation between the Cardioscint detector and the gamma camera was excellent (r = 0.94, SEE +/- 2.1). This detector system has high temporal (10 msec) resolution, and comparison of peak filling rate (PFR) and time to peak filling (TPFR) also showed close agreement with the gamma camera (PFR, r = 0.94, SEE +/- 0.17; TPFR, r = 0.92, SEE +/- 6.8). In 18 patients on bed rest the long-term stability of this system for measuring ejection fraction and ST segments was verified. During the monitoring period (108 +/- 28 minutes) only minor changes in ejection fraction occurred (coefficient of variation 0.035 +/- 0.016) and ST segment analysis showed no significant change from baseline. To determine whether continuous on-line measurement of ejection fraction would be useful after coronary angioplasty, 12 patients who had undergone a successful procedure were evaluated for 280 +/- 35 minutes with the Cardioscint system.(ABSTRACT TRUNCATED AT 250 WORDS)
Authors:
W M Breisblatt; D S Schulman; W P Follansbee
Related Documents :
12514665 - Prognostic value of qt interval and qt dispersion in patients with left ventricular sys...
1282615 - Effects of calcium antagonists in patients with coronary disease and heart failure: lef...
7868285 - Plasma renin activity in chagasic patients with and without congestive heart failure.
17670755 - Echocardiographic and functional cardiopulmonary problems 6 months after first-time pul...
22494955 - Prediction of potential for organ donation after cardiac death in patients in neurocrit...
15017655 - Klebsiella oxytoca as an agent of antibiotic-associated hemorrhagic colitis.
Publication Detail:
Type:  Journal Article; Research Support, Non-U.S. Gov't    
Journal Detail:
Title:  American heart journal     Volume:  121     ISSN:  0002-8703     ISO Abbreviation:  Am. Heart J.     Publication Date:  1991 Jun 
Date Detail:
Created Date:  1991-06-26     Completed Date:  1991-06-26     Revised Date:  2007-11-15    
Medline Journal Info:
Nlm Unique ID:  0370465     Medline TA:  Am Heart J     Country:  UNITED STATES    
Other Details:
Languages:  eng     Pagination:  1609-17     Citation Subset:  AIM; IM    
Affiliation:
Division of Cardiology, University of Pittsburgh School of Medicine, PA.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Adult
Aged
Angioplasty, Transluminal, Percutaneous Coronary*
Diagnosis, Computer-Assisted*
Electrocardiography
Evaluation Studies as Topic
Female
Heart / radionuclide imaging*
Humans
Male
Middle Aged
Monitoring, Physiologic / instrumentation*
Postoperative Period
Stroke Volume
Ventricular Function, Left*

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Prevention of restenosis by lovastatin after successful coronary angioplasty.
Next Document:  Valve deformity and balloon mechanics in percutaneous transvenous mitral commissurotomy.