Abstract/OtherAbstract:
|
Real-time continuous glucose monitoring (RT-CGM) has the potential to revolutionise the care and treatment of individuals with type 1 diabetes (T1D). During the past three years, several devices to measure the interstitial fluid intermittently or continuously have been developed and approved as an adjunct to blood glucose monitoring for use in individuals with T1D. Original studies using these earlier devices showed promise in lowering HbA1c in selected individuals with suboptimal control (1). The first randomised controlled trial with a subcutaneous continuous sensor demonstrated a significant decrease in HbA1c in adult and paediatric patients with poor metabolic control using the RT-CGM device continuously for 3 months compared with the self-monitoring of blood glucose (SMBG) control group (2). Recent randomised controlled trials clearly demonstrated that RT-CGM can significantly reduce HbA1c. Additionally, retrospective use of CGM data can positively affect metabolic control in both type 1 and type 2 diabetes. |
| | |
Authors:
|
B W Bode; T Battelino |
Related Documents
:
|
16224938 - Monitoring glycemic control: the importance of self-monitoring of blood glucose. 21726808 - Acetylation regulates gluconeogenesis by promoting pepck1 degradation via recruiting th... 18056888 - Relationship of a1c to glucose concentrations in children with type 1 diabetes: assessm... 17200278 - Will esophageal impedance replace ph monitoring? 17353188 - Reduction of low molecular weight protein-tyrosine phosphatase expression improves hype... 16631808 - Overcoming the hurdles to achieving glycemic control. |
Publication Detail:
|
Type: Journal Article; Review |
Journal Detail:
|
Title: International journal of clinical practice. Supplement Volume: - ISSN: 1368-504X ISO Abbreviation: Int J Clin Pract Suppl Publication Date: 2010 Feb |
Date Detail:
|
Created Date: 2010-04-09 Completed Date: 2010-10-08 Revised Date: - |
Medline Journal Info:
|
Nlm Unique ID: 9712380 Medline TA: Int J Clin Pract Suppl Country: England |
Other Details:
|
Languages: eng Pagination: 11-5 Citation Subset: IM |
Affiliation:
|
Atlanta Diabetes Associates77 Collier Rd. Suite 2080, Atlanta, GA 30309, USA. bode001@aol.com |
Export Citation:
|
APA/MLA Format Download EndNote Download BibTex |
| MeSH Terms | |
Descriptor/Qualifier:
|
Blood Glucose Self-Monitoring* Diabetes Mellitus / prevention & control Humans Monitoring, Ambulatory |
From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine
Previous Document: Self-monitoring of blood glucose.
Next Document: Insulin pumps.