Continuous cardiac output monitoring with pulse contour analysis: a comparison with lithium indicator dilution cardiac output measurement.
MedLine Citation:
PMID:  16148474     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
OBJECTIVE: Pulse contour analysis can be used to provide beat-to-beat cardiac output (CO) measurement. The current study sought to evaluate this technique by comparing its results with lithium dilution CO (LiCO) measurements. DESIGN: Prospective, observational study. SETTING: Surgical intensive care unit. PATIENTS: Twenty-two patients after cardiac or major noncardiac surgery. MEASUREMENTS: After initial calibration of the pulse contour CO (PCO) method, CO was measured by PCO and by LiCO methods at 4, 8, 16, and 24 hrs. Recalibration of PCO was performed every 8 hrs. The systemic vascular resistance and dynamic response characteristics of the arterial catheter-transducer system were measured at each time point to determine whether these influenced the agreement between PCO and LiCO methods. MAIN RESULTS: There was an excellent correlation between methods (r = .94). Bias was small (-0.005 L/min), and clinically acceptable limits of agreement were demonstrated between techniques. Although many catheter-transducer systems had poor dynamic response characteristics, this did not influence the level of agreement between the two techniques. An increase in systemic vascular resistance between two time points did tend to cause overestimation of LiCO by the PCO. CONCLUSIONS: PCO measurement compared well with the lithium dilution method and can be considered an accurate technique for measuring beat-to-beat CO with limited risk to the patient.
Authors:
James Pittman; Shahar Bar-Yosef; John SumPing; Matthew Sherwood; Jonathan Mark
Related Documents :
10150624 - The paradoxical pulse in tamponade: mechanisms and echocardiographic correlates.
491734 - Measurement of postoperative cardiac output by thermodilution in pediatric and adult pa...
2151114 - Long-term echocardiographic examinations in chronic hemodialysis patients substituted w...
12185434 - Effect of the degree of tricuspid regurgitation on cardiac output measurements by therm...
9845564 - Intraoperative laser doppler flowmetry: a predictor of ischemic injury in acute mesente...
17661774 - Off-pump insertion of continuous flow left ventricular assist devices.
Publication Detail:
Type:  Comparative Study; Journal Article; Research Support, Non-U.S. Gov't    
Journal Detail:
Title:  Critical care medicine     Volume:  33     ISSN:  0090-3493     ISO Abbreviation:  Crit. Care Med.     Publication Date:  2005 Sep 
Date Detail:
Created Date:  2005-09-08     Completed Date:  2005-11-02     Revised Date:  2006-11-15    
Medline Journal Info:
Nlm Unique ID:  0355501     Medline TA:  Crit Care Med     Country:  United States    
Other Details:
Languages:  eng     Pagination:  2015-21     Citation Subset:  AIM; IM    
Affiliation:
Duke University Medical Center and Durham Veterans Affairs Medical Center, Durham, NC, USA.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Cardiac Output / physiology*
Catheterization
Humans
Indicator Dilution Techniques*
Lithium Chloride / diagnostic use*
Male
Middle Aged
Monitoring, Physiologic / methods*
Postoperative Care
Prospective Studies
Pulse*
Transducers
Vascular Resistance / physiology
Chemical
Reg. No./Substance:
7447-41-8/Lithium Chloride

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Recruitment maneuver and high positive end-expiratory pressure improve hypoxemia in patients after p...
Next Document:  The effect of process control on the incidence of central venous catheter-associated bloodstream inf...