Document Detail


Continuous Noninvasive Hemoglobin Monitor from Pulse Ox: Ready for Prime Time?
MedLine Citation:
PMID:  23196342     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
BACKGROUND: Advances in technology have allowed for continuous noninvasive hemoglobin monitoring (SpHb), which may enable earlier detection of hemorrhage and more efficient surgical and/or blood transfusion management. The use of SpHb has not been described in the trauma population. The purpose of the present study was to evaluate the accuracy of a SpHb measurement device in severely injured trauma patients. METHODS: We performed a prospective cohort analysis of severely injured trauma patients admitted to the intensive care unit (ICU) at our level I trauma center over a 6 month period. Serial IHb (invasive hemoglobin) levels and SpHb for the first 72 h were measured. Each SpHb measurement was matched with a corresponding IHb measurement. We defined normal Hgb as >8 mg/dL and low Hgb as <8 mg/dL. Data were then grouped based on Hgb level. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), accuracy, and Spearman correlation coefficient plot were calculated. RESULTS: A total of 23 trauma patients with 89 data pairs were reviewed. Eighty-six percent of the patients were male with a mean age of 32 years and a mean injury severity score (ISS) of 21.1 ± 14. Invasive hemoglobin had a range of 7.2-16.9 and SpHb had a range of 3.3-15.2. The average mean and difference between IHb and SpHb were 10.7 and 1, respectively. Continuous noninvasive hemoglobin measurement did not record data points 13.5 % of the time. The Spearman correlation plot revealed a correlation of R = 0.670 (p < 0.001). After dichotomization with Hgb > 8, SpHb was found to have a sensitivity of 91 %, PPV 96 %, specificity 40 %, NPV 20 %, and an accuracy of 88 %. CONCLUSIONS: The continuous noninvasive hemoglobin monitor does not appear to represent serum hemoglobin levels accurately in severely injured trauma patients. However, we were able to identify utility for this noninvasive tool when Hgb was dichotomized into normal or low levels.
Authors:
Bellal Joseph; Pantelis Hadjizacharia; Hassan Aziz; Kara Snyder; Julie Wynne; Narong Kulvatunyou; Andrew Tang; Terence O'Keeffe; Rifat Latifi; Randall Friese; Peter Rhee
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2012-11-30
Journal Detail:
Title:  World journal of surgery     Volume:  -     ISSN:  1432-2323     ISO Abbreviation:  World J Surg     Publication Date:  2012 Nov 
Date Detail:
Created Date:  2012-11-30     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  7704052     Medline TA:  World J Surg     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Affiliation:
Department of Surgery, University of Arizona, Tucson, AZ, USA, bjoseph@surgery.arizona.edu.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  The Prehospital Burden of Disease due to Trauma in KwaZulu-Natal: The Need for Afrocentric Trauma Sy...
Next Document:  Poly(DL-lactide-co-glycolic acid) Nanoparticle Design and Payload Prediction: A Molecular Descriptor...