Abstract/OtherAbstract:
ABSTRACT: The use of Focused Ion Beam (FIB) instrument's to analyze and prepare samples that are radioactive requires attentiveness to the materials that are dislodged and free inside the chamber. Radioactive sputtered material must be understood even when observed at trace concentrations. Measurements using liquid scintillation counting and high purity germanium detectors were used to evaluate contamination on accessible surfaces inside a focused ion beam chamber that was used in the preparation of samples that were radioactive. The maximum removable contamination found was 0.27 0.4 Bq cm, on the focused ion beam wall with 0.24 0.019 Bq cm on the door. Although these magnitudes of removable contamination are inconsequential for activation products, these same magnitudes of actinides, for example Pu, would represent 3.2% of an Annual Limit of Intake. This might be considered significant if one examines the relatively infrequent use of this device for the preparation of radioactive samples. Predicted activities of sputtered material were found using the software Transport of Ions in Matter, estimating that 0.003% of a radioactive samples activity is released into the FIB chamber. A used secondary electron detector's activity was measured to be 383.7 8.1 Bq. Preferential build-up of sputtered materials due to temperature or static charge gradients was considered. No temperature gradients were observed. Static charge gradients were measured inside the chamber varying between 0.057% below the mean to 34% higher than the mean. However, the magnitudes of contamination measured did not correlate to static charge gradients. Deposition in the chamber appears to have no mechanical cause but rather is sporadic however, measureable. Experience to date has been limited to samples of low activity; nevertheless, contamination inside the chamber was observed. Users should anticipate higher levels of readily dispersible radioactive contamination within the FIB as sample activity increases.
Authors:
Audrey Ruth Evelan; Richard R Brey
Related Documents :
24310966 - Influence of bovine serum albumine on the proton conductance of potato mitochondria mem...
1387896 - Freeze-fracture study of the site of attachment of cryptosporidium muris in gastric gla...
20388516 - Salicylate-induced translocation of prestin having mutation in the gtsrh sequence to th...
632326 - Freeze-fracture observations of the lactating rat mammary gland. membrane events during...
15617826 - Development and initial evaluation of peg-stabilized bilayer disks as novel model membr...
6467016 - Dolichol deposition in developing mammalian brain: content of free and fatty-acylated d...
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Health physics     Volume:  104     ISSN:  1538-5159     ISO Abbreviation:  Health Phys     Publication Date:  2013 Feb 
Date Detail:
Created Date:  2013-01-04     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  2985093R     Medline TA:  Health Phys     Country:  United States    
Other Details:
Languages:  eng     Pagination:  S23-30     Citation Subset:  IM    
Affiliation:
*Idaho State University, 785 South 8th Avenue, Mail Stop 83103, Pocatello ID, 83209.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Informed consent in human research: what to say and how to say it.
Next Document:  Applying Image GentlySM and Image WiselySM in Nuclear Medicine.