Within continuously controlled limits of cuff pressure, an endotracheal tube cuff made of polyurethane (PU) prevents secretion inflow better than a conventional polyvinylchloride cuff. However, the temperature difference between ventilator gas and the air inside a PU cuff produces condensation droplets that accumulate in the cuff inflation canal. We investigated whether condensation influenced continuous cuff pressure monitoring. A PU-cuffed tube was placed into an artificial trachea and connected to a ventilator and test lung. An additional line was inserted at the distal cuff end to directly measure pressure inside the cuff. Methylene blue instillation via the inflation line mimicked condensation. Inspiratory (Pinsp) and expiratory (Pexp) pressures were continuously recorded. Six consecutive experiments were performed comparing pressures at baseline (T0) and at 24 h (T24). Shortly after dye instillation, pressures recorded at the inflation canal became permanently fixed at 25 cmH2O. In contrast, pressures measured directly in the cuff progressively decreased (mean Pinsp 30 ± 3 vs. 20 ± 2 cmH2O and mean Pexp 25 ± 0 vs. 12 ± 2 cmH2O, T0 vs. T24, both P < 0.05). Thus, condensation in the inflation line of a PU-cuffed tube renders continuous cuff pressure monitoring unreliable, thereby increasing the risk for microaspiration.
Authors:
Herbert Spapen; Walter Moeyersons; Wim Stiers; Geert Desmet; Emiel Suys
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2014-5-23
Journal Detail:
Title:  Journal of anesthesia     Volume:  -     ISSN:  1438-8359     ISO Abbreviation:  J Anesth     Publication Date:  2014 May 
Date Detail:
Created Date:  2014-5-23     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  8905667     Medline TA:  J Anesth     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Anesthetic management of pulmonary valve replacement for pulmonary regurgitation in six patients wit...
Next Document:  Dexmedetomidine suppresses long-term potentiation in the hippocampal CA1 field of anesthetized rats.