Document Detail


Complications with permanent endocardial electrode systems.
MedLine Citation:
PMID:  1070219     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
The different complications of endocardial electrode systems in 185 patients during the last seven years are discussed. The surgical technique for the now routinely used cephalic route is described. The choice of anaesthesia is discussed. In the last 39 implantations there have not been any displacements or retractions. Of the total number of patients only 3 required replacement of endocardial by myocardial electrodes. This was caused by unstable position and high stimulation threshold. Fracture of the electrode occurred in 4 cases. Stimulation of the diaphragm occurred in 10%, displacement and retraction of the electrodes in 6,5% and heart penetration or perforation in 3,8% of the patients. There was one death from cardiac tamponade due to electrode perforation of the right ventricle. One case had irreversible brain damage due to prolonged asystole during pulse generator replacement. Unimportant wound infections and haematomas occurred in 5 patients and phlebitis in 3 patients. More or less serious electrode complications have been seen in 56 of the 185 patients, 18 patients having more than one complication.
Authors:
O J Ohm; L Segadal; D W Skagen
Related Documents :
16915769 - Compression entropy contributes to risk stratification in patients with cardiomyopathy.
18354369 - General anaesthesia in a patient affected by brugada syndrome.
19075519 - Recovery of cardiomegaly after treatment of traumatic popliteal arteriovenous fistula.
20592999 - Anesthetic considerations in a patient with amiodarone-induced thyrotoxicosis.
8015009 - Blunt traumatic rupture of the heart: an experience in tokyo.
9191509 - Sudden cardiac death in the adult with congenital heart disease.
18033989 - Radiculopathy index: a proposition of uniformed clinical examination in cervical radicu...
8522319 - Genotype-phenotype correlation in a series of 167 deletion and non-deletion patients wi...
12053129 - Neuropsychological deficit in early subcortical vascular dementia: comparison to alzhei...
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Acta medica Scandinavica. Supplementum     Volume:  596     ISSN:  0365-463X     ISO Abbreviation:  Acta Med. Scand. Suppl.     Publication Date:  1976  
Date Detail:
Created Date:  1977-02-24     Completed Date:  1977-02-24     Revised Date:  2005-02-14    
Medline Journal Info:
Nlm Unique ID:  0370331     Medline TA:  Acta Med Scand Suppl     Country:  SWEDEN    
Other Details:
Languages:  eng     Pagination:  22-9     Citation Subset:  IM    
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Electrodes, Implanted*
Endocardium
Heart Injuries / etiology
Humans
Necrosis
Pacemaker, Artificial / adverse effects*,  methods
Phlebitis / etiology
Skin / pathology
Surgical Wound Infection / etiology

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Pacemaker wires and electrodes. A follow-up study.
Next Document:  Displacement of endocardial pacemaker electrodes. A comparison between Elema 588 B and Chardack 5818...